摘要 关节摩擦副运动过程中产生的磨损颗粒,含有大量详尽而重要的摩擦学信息,反映和代表了置换关节不同的磨损形式和机制。利用原子力显微镜技术的定量纳米力学性能测试模式在纳米尺度对UHMWPE磨粒的机械性能、三维几何轮廓以及表面形貌进行考察,并将不同类型磨粒以及聚乙烯基体材料的各种特性进行对比研究。实验结果显示,纳米级和亚微米级磨粒的弹性模量明显较高,且磨粒表面较为平滑;而微米级磨粒和聚乙烯基体材料的弹性模量较小,磨粒表面较为粗糙。分析认为,微米级磨粒是由于聚乙烯材料宏观尺度上的黏着磨损产生;而纳米级和亚微米级磨粒是由于乙烯材料微观尺度上的磨料磨损产生。该分析结果将有利于进一步了解人工关节材料的磨损机制以及磨粒产生的机制。 The wear particles are important information carriers about microscopic wear mechanisms of artificial hip joint components. Atomic force microscopy (AFM) was used to quantify wear particle topographic features and nano-mechanical properties. The mechanical properties and topographic character of the UHMWPE material indicate that the nano- and submicron-sized particles have a much greater modulus and smoother surface than the micron-sized particles and bulKpolymer samples. These differences reveal that the micron particles are most likely to be produced under macroscopic polymer asperity wear, while the nano- and submicron-sized particles are generated under microscopic polymer asperity wear. These findings provide a deeper understanding of the wear mechanism and processes of wear particle generation.
出处 《润滑与密封》 CAS CSCD 北大核心 2013年第7期1-7,共7页 Lubrication Engineering
基金 霍英东教育基金会高等院校青年教师基金项目(131051)
关键词 人工髋关节 磨粒 原子力显微镜 机械性能 artificial hip joint wear particles AFM mechanical property
  • 相关文献

参考文献30

  • 1Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement [J]. Proceedings of the Institution of Mechanical Engineers: Part H: Journal of Engineering in Medicine,2000,214( 1 ) : 21 - 37.
  • 2Matthews J B, Besong A A, Green T R, et al. Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose [ J ].Journal of Biomedical Materials Research, 2000, 52:296 - 307.
  • 3Yang S Y, Ren W P, Park Y S, et al. Diverse cellular and apoptotie responses to variant shapes of UHMWPE particles in a murine model of inflammation [ J ]. Biomaterials, 2002,23 (17) - 3535 - 3543.
  • 4Sieving A, Wu B, Mayton L, et al. Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene ( UHMWPE ) wear debris that provoke inflammation in a murine model of inflammation [ J]. Journal of Biomedical Materials Research:Part A,2003,64A(3 ) : 457 - 464.
  • 5Edidin A A, Pruitt L, Jewett C W, et al. Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE aeetabular components for total hip replacement [ J]. The Journal of Arthroplasty, 1999,14 (5) : 616 - 627.
  • 6Wang A, Sun D C, Yau S S, et al. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene [ J ]. Wear, 1997,203/204 : 230 - 241.
  • 7Moradi M, Fereidon A H, Sadeghzadeh S. Dynamic modeling for nanomanipulation of polystyrene nanorod by atomic force microscope [ J ]. Scientia Iranica,2011,18 ( 3 ) : 808 - 815.
  • 8Derjaguin B V, Muller V M, Toporov Y P. Effect of contact deformations on the adhesion of particles [ J ]. Journal of Colloid and Interface Science, 1975,53 (2) : 314 -326.
  • 9Young T J, Monclus M A, Burnett T L, et al. The use of the PeakForceTM quantitative nanomechanical mapping AFM- based method for high-resolution Young's modulus measurement of polymers [ J ]. Measurement Science and Technology, 2011, 22:1-6.
  • 10Kurtz S M. UHMWPE biomaterials handbook: a primer on UHMWPE [ M ]. 2nd ed. Boston: Academic Press ,2009.

二级参考文献35

  • 1张德添,张飒,何昆,杨怡,周涛,张英鸽.原子力显微镜在生物医学中的应用[J].现代仪器,2004,10(4):1-5. 被引量:6
  • 2Kuster M S, Podsiadlo P, Stachowiak G W. Shape of wear particles found in human knee joints and their relationship to osteoarthritis[ J ]. British Journal of Rheumatology, 1998,37 : 978 - 984.
  • 3Graindorge S L,Stachowisk G W. Changes occurring in the surface morphology of articular cartilage during wear [ J ]. Wear, 2000,241 : 143 - 150.
  • 4Fisher J. A novel method for the prediction of functional biological activity of polyethylene wear debris [ J ]. Proe Instn Meeh Engrs,2001,215 :127 - 132.
  • 5Peng Z. Osteoarthfitis diagnosis using wear particle analysis technique : investigation of correlation between particle and cartilage surface in walking process [ J ]. Wear,2007,262:630 - 640.
  • 6Podsiadlo P, Kuster M, Stachowiak G W. Numerical analysis of wear particles from non-arthritic and osteoarthritic human knee joints [ J]. Wear, 1997,210:318 - 325.
  • 7Tomovieh S,Peng Z. The development of a new image acquisition & analysis system for 3D surface measurements using confocal laser scanning microscopy [ J ]. Advanced Materials Research ,2008,32 : 173 - 179.
  • 8Oyen M L. Nanoindentation hardness of mineralized tissues [ J ]. Journal of Biomechanics,2006 ,39 :2699 - 2702.
  • 9Groover M P. Fundamentals of Modern Manufacturing[ M]. New Jersey:John Wiley and Sons Inc. ,2007:51 -56.
  • 10Franke O, Durst K, Maier V, et al. Mechanical properties of hyaline and repair cartilage studied by nanoindentation [ J]. Acta Biomaterialia ,2007,3:873 - 881.