摘要 目的探讨徒手植入寰椎侧块螺钉与枢椎椎弓根螺钉方法,总结临床应用经验及效果。方法临床寰枢椎不稳患者16例,男11例,女5例,平均37.5岁;应用钉棒系统。后路正中切口显露寰椎后弓及枢椎椎板,寰椎侧块螺钉进钉点选择在寰椎后结节中点旁开18~20 mm,与后弓下缘以上2 mm的交点,钉道方向在冠状面垂直,矢状面上螺钉头端向头侧倾斜约5°。枢椎进钉点为枢椎下关节突根部中点,钉道与矢状面夹角约15°,横断面夹角约30°。术前JOA评分58~102分,平均72分。结果术后无1例发生脊髓和椎动脉损伤。随访7~22个月,平均15个月,JOA评分131~163分,平均145分,改善率86.4%。植骨块全部融合,无内固定断裂、松动。结论寰椎侧块螺钉与枢椎椎弓根螺钉徒手植入技术简单、可靠,值得推广。 【Objective】To explore unarmed implant atlas lateral mass screws and atlas vertebral pedicle screws and clinical application experience and effect.【Method】Clinical vertebral instability between atlas 16 cases of patients,male,female 11 cases in 5 cases,an average of 37.5 years;Application was great system.The center of the posterior incision atlas bow and hub after the presence of cervical board,atlas lateral mass screws into the nails point selection in the halfway point after atlas nodules open 18~20 mm,and inferior after more than 2 mm bow intersection of the way,nailing direction in the coronal vertical sagittal plane,head to head the screw side tilt about 5°.Atlas and nail into point as atlas of the joint to root the midpoint of nail,tao and sagittal Angle about 15°,about 30° cross-sectional Angle.Preoperative JOA scoring 58 to 102 points,an average of 72 points.【Results】No one case had spinal cord and vertebral artery injury.Follow-up was 7 ~22 months with an average of 15 months,JOA rating was 131~163 points,an average of 145 points,86.4% was improved.All bone graft was fused without inner fixed fracture and loose.【Conclusion】Atlas lateral mass screws and atlas vertebral pedicle screws unarmed implant technology is simple,reliable,worthy to be popularized.
出处 《中国现代医学杂志》 CAS CSCD 北大核心 2013年第16期95-98,共4页 China Journal of Modern Medicine
关键词 寰枢椎 螺钉 徒手技术 内固定 between atlas vertebral screw unarmed technology internal fixation
  • 相关文献

参考文献11

二级参考文献23

  • 1张汉伟,王树荚,苏池新.经口咽切除齿状突(附6例报告)[J].中华神经外科杂志,1996,12(3):179-180. 被引量:4
  • 2[4]Resnick DK, Lapsiwala S, Trost GR. Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine, 2002;27(14):1 494
  • 3[6]Resnick DK, Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery, 2002; 50(2): 426
  • 4[7]Brantley AG, Mayfield JK, Koeneman JB, et al. The effects of pedicle screw fit. An in vitro study. Spine,1994;19(15):1 752
  • 5[8]Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine, 2001;26(22):2 467
  • 6Magerl F,Seemann PS.Stable Posterior Fusion of the Atlas and Axis by Transarticular Scsew Fixation[M].In:Kehr P,Weidner A(eds).Cervical Spine 1.Vienna:Springer-verlag,1987.322-327.
  • 7Fang HSY, Ong GB. Direct approach to the upper cervical spine[J].J Bone Joint Surg(Am),1962,44:1588-1604.
  • 8Tuite GF, Veres R, Crockard HA, et al. Pediatric transoral surgery:indications complications,and loug-term outcome[J].J Neurosurg, 1996, 84(4) :573 -583.
  • 9Behari S, Banerji D,Bhargava V,et al.Transoral decompression for craniovertebral osseous anomalies:perioperative management dilemmas[J].Neurological Society of India,1999,47(3):188-195.
  • 10Hajek PD,Lipka J,Hartline P,et al.Biomachanical study of C1-2 posterior arthrodesis techniques[J].Spine,1993,18(2):173.

共引文献348

同被引文献15

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部