针对长钢连轧厂汽化冷却系统的故障分析,采取了6项改进措施,从而彻底解决了炉筋管烧坏变形问题,大大提高了加热炉有效作业率。
Six measures are put forward and utilized after the malfunction of evaportion cooling system of furnace is analyzed in Continuous Rolling Plant,Changzhi Iron and Steel Company. The problem of deformation of furnace ribbed tube can be completely resolved. Then operating rate of furmace is increased.