摘要 介绍了燃气-蒸汽联合循环中余热锅炉停炉腐蚀的原理和保护的方法,并以北京京桥热电1号余热锅炉为例,介绍了在调试期间该锅炉采用的氨-联氨钝化烘干法以及冲氮湿法保养的原理和具体的操作步骤,同时提出了采用不同方法进行保养时需要注意的事项。 In this paper, the stopped boiler corrosion principles and protection methods of Heat Recovery Steam Generator (HRSG) of combined gas-stream cycle unit are introduced. The HSRG No. 1 in Beijing Jingqiao thermal plant is taken as an example to introduce the maintenance principle and the concrete operating procedures of ammonia-hydrazine passivation drying method and rushed nitrogen wet maintenance method used during commissioning of the boiler. And the attention points of different maintenance methods are proposed.
出处 《华北电力技术》 CAS 2013年第7期21-25,共5页 North China Electric Power
关键词 余热锅炉 停炉保养 联氨钝化烘干 冲氮湿法保养 HRSG shutdown maintenance hydrazine passivation drying punch nitrogen wet maintenance