期刊文献+

焦炉烟道气余热利用的不足与改进 被引量:4

Disadvantages and improvement for waste heat utilization from coke oven waste gas flue
下载PDF
导出
摘要 总结了焦炉烟道气余热回收装置投产初期出现的问题,并通过增加开孔及管道横截面积减少系统阻力,采用变频调节增加总烟道吸力,增设烟道电动插板阀隔断废气循环等措施,使烟道气余热回收装置达到设计效果。 This paper summarized the defects of waste heat recovery unit from coke oven waste gas flue at the initial stage after commissioning and proposed some measures such as by increasing holes and cross section of pipes to reduce system resistance,by using VVVF to increase suction of common waste gas flue and by adding additional motorized flap valve to cut off waste gas circulation, etc. so that the waste gas heat recovery unit can reach up to designed target.
出处 《燃料与化工》 2013年第4期36-37,共2页 Fuel & Chemical Processes
关键词 焦炉烟道气 余热回收装置 烟道吸力 Coke oven waste gas flue Waste gas recovery unit Waste gas flue suction