摘要 在南水北调天津市市内配套西河原水枢纽泵站工程设计中,针对三个水厂的不同规模,考虑最高日平均时用水量进行了水泵选择。该工程设计输水规模为225×104m3/d,建成投产后,将为天津市市内三大水厂提供引江原水。 In the design of Xihe raw water pumping station which is an auxiliary project of South- to-North Water Diversion in Tianjin, aimed at the different sizes of three water plants, the pumps were selected by taking the maximum daily average water consumption into account. The design capacity of the project is 225×10^4m^3/d. The Xihe junction pumping station will provide the raw water from river for three waterworks in Tianjin City after its completion and putting into operation.
出处 《中国给水排水》 CAS CSCD 北大核心 2013年第14期56-58,共3页 China Water & Wastewater
关键词 引江原水 泵站 水泵 raw water from river pumping station pump
  • 相关文献

参考文献3

  • 1GB50013-2006,室外给水设计规范[S].北京:中国计划出版社,2006.
  • 2张中和.给水排水设计手册[M].北京:中国建筑工业出版社,2002.
  • 3GB 50265—2010,泵站设计规范[S].北京:中国计划出版社,2010.