摘要 采用低氮燃烧+选择性非催化还原烟气脱硝技术对循环流化床锅炉烟气进行脱硝处理。烟气NOx初始浓度为280 mg/Nm3时,排放浓度低于100 mg/Nm3,去除率达65%以上。达到国家《火电厂大气污染物排放标准(GB13223-2011)》限值要求。工艺稳定运行后年处理费用为202.40万元。 Low NOx combustion + SNCR technology is designed to treat the flue gas deNOx of CFB boilers. When the NOx concentration of intake gas were 280 mg/Nm3, the effluent gas were below 100 mg/Nm3. And the removal rate reached 65%. The gas quality of effluent after this treatment can reach the Emission Standard of Air Pollutants for Thermal Power Plants (GB13223-2011). It will cost 2.024 millions per year to treat the gas when the system is stable.
作者 陈杏
出处 《能源环境保护》 2013年第4期33-35,共3页 Energy Environmental Protection
关键词 低氮燃烧 SNCR 循环流化床锅炉 烟气脱硝 Low NOx combustion SNCR CFB Flue gas DeNOx
  • 相关文献

参考文献4

二级参考文献8

  • 1张晓梅.燃煤锅炉机组[M].2版.北京:中国电力出版社,2006.
  • 2Jiang Pengzhi.Application of Low NOx Burner Technology to Chinese Boilers and Chinese Fuels[].PowerGen Asia.2006
  • 3Bowman C.T.Control of Combustion-Generated Nitrogen Oxide Emission:Technology Driven by Regulation[].~ (th) Symp (Intl) Comb.
  • 4W.Goodrich,M.Sandell,V.Petti,L.Rettura.Summary of Air Emissions from the First Year Operation of JEA‘s Northside Generating Station[].ICAC Furum.2003
  • 5Garcia-Mallol J A,Steitz T,Chu C Y,et al.Ultra-lowNOxadvanced FW arch firing:Central power station applications[].Proceedings ofthend USChina NOxand SOControl Workshop.2005
  • 6Robert A Dyr,Jerry L Hebb,Scott L Darling.The JEA CFB Demonstration Project: An Update. http://www.fwc.com/publications/tech_papers . 2000
  • 7Warnatz J,Maas U,Dibble R W.Combustion[]..1999
  • 8罗朝晖,王恩禄.循环流化床锅炉选择性非催化还原技术及其脱硝系统的研究[J].动力工程,2008,28(3):442-446. 被引量:38

共引文献66

同被引文献77

引证文献11

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部