期刊文献+

Three-dimensional mapping and comparative analysis of the distal human corpus cavernosum and the inflatable penile prosthesis

Three-dimensional mapping and comparative analysis of the distal human corpus cavernosum and the inflatable penile prosthesis
下载PDF
导出
摘要 The intricate anatomy of the corpus cavernosum in both the flaccid and tumescent state has not been fully elucidated. We report our experience using a three-dimensional (3D) scanner to reconstruct cadaveric casts and compare them with 3D images of two prototypes of penile prosthesis. Two different models of the Titan Coloplast inflatable penile prosthesis were analyzed using a 3D scanner. The first was the standard model and the second was a newer model with a rounder silicone tip. Two cadaveric phalluses were harvested using Smooth-Cast 300Q polyurethane molding. The molds were excised and scanned along side the penile prosthesis. 3D scans were completed and analyzed using Leios Mesh software, and GOM Inspect software. The 3D scans demonstrated the mean human corporal radii 2 mm from the distal tip to be 36.51 mm (36.01-37.0 mm), which is an obtuse angle. The standard Titan penile prosthesis spherical radius at the same level was 202.52 mm, while the new silicone tip prosthesis had a radius of 139.33 mm. 3D mapping further demonstrated the trajectory of the cavernosa appeared curvilinear and the distal ends appeared blunt. The use of cadaveric cavernosal molds in combination with the 3D scanner allowed us to accurately image the corpus cavernosum for the first time. Our findings suggest that anatomically accurate corporal tips appear to be relatively blunt and that the new Titan silicone tip penile prosthesis more closely resembles the human corporal tip. The intricate anatomy of the corpus cavernosum in both the flaccid and tumescent state has not been fully elucidated. We report our experience using a three-dimensional (3D) scanner to reconstruct cadaveric casts and compare them with 3D images of two prototypes of penile prosthesis. Two different models of the Titan Coloplast inflatable penile prosthesis were analyzed using a 3D scanner. The first was the standard model and the second was a newer model with a rounder silicone tip. Two cadaveric phalluses were harvested using Smooth-Cast 300Q polyurethane molding. The molds were excised and scanned along side the penile prosthesis. 3D scans were completed and analyzed using Leios Mesh software, and GOM Inspect software. The 3D scans demonstrated the mean human corporal radii 2 mm from the distal tip to be 36.51 mm (36.01-37.0 mm), which is an obtuse angle. The standard Titan penile prosthesis spherical radius at the same level was 202.52 mm, while the new silicone tip prosthesis had a radius of 139.33 mm. 3D mapping further demonstrated the trajectory of the cavernosa appeared curvilinear and the distal ends appeared blunt. The use of cadaveric cavernosal molds in combination with the 3D scanner allowed us to accurately image the corpus cavernosum for the first time. Our findings suggest that anatomically accurate corporal tips appear to be relatively blunt and that the new Titan silicone tip penile prosthesis more closely resembles the human corporal tip.
出处 《Asian Journal of Andrology》 SCIE CAS CSCD 2013年第4期567-570,I0012,共5页 亚洲男性学杂志(英文版)
关键词 corpus cavernosum penile prosthesis three-dimensional analysis corpus cavernosum penile prosthesis three-dimensional analysis
  • 相关文献

参考文献8

  • 1Wahle GR, Mulcahy JJ. Ventral penile approach in unitary component penile prosthesis placement. J Urol 1993; 149: 537-8.
  • 2Lue TF, Basson R, Rosen R, Guiliano F, Khoury S et al. Sexual Medincine: Sexual Dysfunction in Men and Women. Paris: Health Publications Limited; 2004. p475-7.
  • 3Deveci S, Martin D, Parker M, Mulhall JP. Penile length alterations following penile prosthesis surgery. Eur Urol 2007; 51: 1128-31.
  • 4Yiee JH, Baskin LS. Penile embryology and anatomy. Sci WorldJ201O; 10: 1174-9.
  • 5Lue TF, Hon S. Physiology of penile erection and pathophysiology of erectile dysfunction. In: Wein AJ, Kavoussi LR, Novick AC, Partoin AW, Peters CA, editors. Campbells Urology. 10th ed. Philadelphia, PA: Elsevier; 2011. p691.
  • 6Hsu GL, Brock G, Martinez-Pineiro L, von Heyden B, Lue TF et al. Anatomy and strength of the tunica abuginea: Its relevance to penile prosthesis exirusion. JUral 1994; 151: 1205-8.
  • 7McPhail EF, Nehra A, Bruner BC, Kawashima A, King BF et al. MRI and its role in the evaluation and surgical decision making in patients with challenging IPP presentations: descriptions of MRI findings and algorhythm for patient management. BJU Int2012; 109: 1848-52.
  • 8Ozsoy U, Demirel BM, Yildirim FB, Tosun 0, Sarikcioglu L. Method selection in craniofacial measurements: advantages and disadvantages of 3D digitization method. J Cranio-Maxillofacial Surg2009; 37: 285-90.