期刊文献+

SPR-微流控芯片技术在医学研究中的应用 被引量:2

Application of SPR-Microfluidic chip technology in medical research
原文传递
导出
摘要 SPR-微流控芯片技术已经成为21世纪最为重要的前沿技术之一,现已广泛应用于生物医学领域。对比传统的研究方法,微流控技术具有微量、快速、自动、可控的特点;SPR技术具有非标记、灵敏、实时、定量检测的特点。它们相结合将具有高灵敏度、高通量、非标记、样品和试剂耗量小等优点,它们的综合应用将会改变现代生物医学研究的格局。SPR-微流控芯片在医学方面的研究取得巨大成就,本文将在细胞、基因、蛋白质、小分子与小离子检测等方面进行综述。 SPR-microfluidic chip technology has become one of the most important cutting-edge technology in twenty-first century,which has been widely used in the biomedical fields.Compared with the traditional research methods,microfluidic technology has trace,fast,automatic,controllable characteristics.SPR has unmarked,sensitive,real-time,quantitative detection characteristics.SPR-microfluidic will combine with high sensitivity,high throughput,label-free,less sample and reagent consumption,their comprehensive application will change the pattern of modern biomedical research.In this paper,SPR-microfluidic chip technology will be reviewed.in the biomedical research advances,including cell research,gene and proteins,small molecules and small ion and so on.
出处 《中国热带医学》 CAS 2013年第5期641-644,共4页 China Tropical Medicine
基金 国家自然科学基金项目(No.30972827 81171667) 深圳市科技研发基金-国际合作项目(No.ZYA201106080020A)
关键词 SPR芯片 微流控芯片 细胞研究 基因研究 蛋白分析 小分子与小离子检测 SPR chip microfluidic chip Cell research Gene research Proteins analysis Small molecule and ion detection
  • 相关文献

参考文献20

  • 1Pimkov6 K,Bockovfi M,Hegnerovd K,et al . Surface plasmon resonance biosensor for the detection of VEGFR-1-a protein marker of myelodysplastic syndromes[J] . Anal Bioanal Chem,2012; 402( 1 ) : 381-7.
  • 2Dudak FC, Boyaci IH . Rapid and label-free bacteria detection by surface plasmon resonance (SPR) biosensors [J] . Biotechnol J, 2009;4(7) : 1003-11.
  • 3Gulnaz Stybayeva, Markhabat Kaimvab, Erlan Ramanculovc,et al . Detecting interferon-gamma release from human CD4 T-cells using surface plasmon resonance [J] . Biointerfaces,2010;9 (80):251- 255.
  • 4Biehsel CA,Gobaa S, Kobel S,et al . Diagnostic micrechip to assay 3D colony-growth potential of captured circulating tumor cells [J] . Lab Chip,2012; 12(13) :2313-6.
  • 5Zhou Y,Pang Y,Huang Y . Openly accessible mierofluidic liquid handlers for automated high-throughput nanoliter cell culture [J] . Anal Chem, 2012; 84( 5 ) : 2576-84.
  • 6Zhang D, Yan Y, Li Q, et al. Label-free and high-sensitive detection of Salmonella using a surface plasmon resonance DNA-based biosensor[J]. J Biotechnol, 2012; 160(3-4) : 123-8.
  • 7Okabe Y,Chen Y,Purohit R,et al.Piezoelectrically driven vertical cavity acoustic transducers for the eonvective transport and rapid detection of DNA and protein binding to DNA mieroarrays with SPR imaging-a parametrie study[J] . Biosens Bioelectron,2012;35 ( 1 ) : 37-43.
  • 8Seefeld TH,Zhou W J, Corn RM. Rapid microarray detection of DNA and proteins in microliter volumes with surface pIasmon resonance imaging measurements[J] . Langmuir. 2011 ;27(10) :6534-40.
  • 9Metzger J,von Landenberg P,Kehrel M,et al . Biosensor analysis of beta2-glycoprotein I-reactive autoantibodies :evidence for isotype- specific binding and differentiation of pathogenie from infection-induced antibodies [ J ]. Clin Chem, 2007; 53 (6) : 1137-43.
  • 10Matharu Z, Bandodkar A J, Sumana G, et al. Low density tipoprotein detection based on antibody immobilized self -assembled monolayer: investigations of kinetic and thermodynamic properties [J]. J Phys Chem B, 2009; 113(43): 14405-12.

同被引文献6

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部