摘要 Accurate stereo vision calibration is a preliminary step towards high-precision visual posi- tioning of robot. Combining with the characteristics of genetic algorithm (GA) and particle swarm optimization (PSO), a three-stage calibration method based on hybrid intelligent optimization is pro- posed for nonlinear camera models in this paper. The motivation is to improve the accuracy of the calibration process. In this approach, the stereo vision calibration is considered as an optimization problem that can be solved by the GA and PSO. The initial linear values can be obtained in the frost stage. Then in the second stage, two cameras' parameters are optimized separately. Finally, the in- tegrated optimized calibration of two models is obtained in the third stage. Direct linear transforma- tion (DLT), GA and PSO are individually used in three stages. It is shown that the results of every stage can correctly find near-optimal solution and it can be used to initialize the next stage. Simula- tion analysis and actual experimental results indicate that this calibration method works more accu- rate and robust in noisy environment compared with traditional calibration methods. The proposed method can fulfill the requirements of robot sophisticated visual operation. Accurate stereo vision calibration is a preliminary step towards high-precision visual posi- tioning of robot. Combining with the characteristics of genetic algorithm (GA) and particle swarm optimization (PSO), a three-stage calibration method based on hybrid intelligent optimization is pro- posed for nonlinear camera models in this paper. The motivation is to improve the accuracy of the calibration process. In this approach, the stereo vision calibration is considered as an optimization problem that can be solved by the GA and PSO. The initial linear values can be obtained in the frost stage. Then in the second stage, two cameras' parameters are optimized separately. Finally, the in- tegrated optimized calibration of two models is obtained in the third stage. Direct linear transforma- tion (DLT), GA and PSO are individually used in three stages. It is shown that the results of every stage can correctly find near-optimal solution and it can be used to initialize the next stage. Simula- tion analysis and actual experimental results indicate that this calibration method works more accu- rate and robust in noisy environment compared with traditional calibration methods. The proposed method can fulfill the requirements of robot sophisticated visual operation.
机构地区 School of Automation
出处 《Journal of Beijing Institute of Technology》 EI CAS 2013年第2期213-221,共9页 北京理工大学学报(英文版)
关键词 robot stereo vision camera calibration genetic algorithm (GA) particle swarm opti-mization (PSO) hybrid intelligent optimization Key words: robot stereo vision camera calibration genetic algorithm (GA) particle swarm opti-mization (PSO) hybrid intelligent optimization
  • 相关文献

参考文献12

  • 1Faugeras O, Toscani G. The calibration problem for stereo[C]//IEEE Computer Society Conference on Computer Vision and Pattern Recognition. Minmi Beach, Florida, USA: IEEE, 1986: 15 -20.
  • 2Abdel-Aziz Y I, Karara H M. Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry [ C ] // Proceeding of the Symposium on Close-Range Photogrammetry. Falls Church, VA: American Society of Photogrammetry, 1971: 1-18.
  • 3Tsai R Y. A versatile camera calibration technique for high accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses [ J ]. IEEE Transactions on Robotics and Automation, 1987, 3.(4) : 323 - 344.
  • 4Weng J, Cohen P, Hemiou M. Camera calibration with distortion models and accuracy evaluation [ J ]. IEEE Trans PAMI, 1992, 14(10) : 965 -980.
  • 5Zhang Zhengyou. A flexible new technique for camera calibration [ J ]. IEEE Transactions on Pattern A-nalysis and Machine Intelligence, 2000, 22 ( 11 ): 1330 -1334.
  • 6Zhang Zhengyou, Zhu Dayong, Zhang Jing, et al. Improved robust and accurate camera calibration method used for machine vision application[ J]. Optical Engineering, 2008, 47(11) : 117201.
  • 7Kumar S, Thakur M, Raman B, et al. Stereo camer-a calibration using real coded genetic algorithm [ C ] //IEEE Region 10 Conference (TENCON). Hyderabad, India: IEEE, 2008: 1 -5.
  • 8Bilal K, Qureshi J. Nature inspired optimization techniques for camera calibration [ C ] // IEEE International Conference on Emerging Technologies. Rawalpindi, Pakistan; IEEE, 2008;27 -31.
  • 9Kumar S, Raman B, Wu J. Neuro-calibration of a camera using particle swarm optimization [ C ]// International Conference on Emerging Trends in Engineering and Technology. Nagpur, India: IEEE 2009; 273 -278.
  • 10Heikkila J. Geometric camera calibration using circular control points[ J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(10) ; 1066 -1077.