Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery 被引量:1

Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
原文传递
导出
摘要 Background Robotic assisted minimally invasive cardiac sugery is a new technique that uses small port sites and peripheral vessel cannulation for cardiopulmonary bypass (CPB) has been used. The right internal jugular vein (IJV) is commonly used for intraoperative venous access to the central circulation and identified with an external landmark. Previous studies have demonstrated the superiority of ultrasound guidance over external landmark technique in anaesthetic and intensive care settings. The aim of the present study was to delineate the utility of ultrasound-guided cannulation of the IJV during establishment of peripheral CPB in robotic cardiac surgery. Methods We prospectively studied 296 adult patients undergoing ultrasound-guided right IJV cannulation during establishment of peripheral CPB in robotic cardiac surgery at our institute from January 2007 to October 2012 (ultrasound group). The success rate, the first attempt success rate, access time and the complication rate of ultrasound-guided method were compared with the landmark-guided method used for 302 historical control patients (landmark group). Results In the ultrasound group, 296 consecutive adult patients underwent ultrasound-guided right IJV cannulation during establishment of peripheral CPB in robotic cardiac surgery. In the landmark group, 302 patients underwent right IJV cannulation using the landmark-guided technique. The success rate and the first attempt success rate in the ultrasound group were significantly higher than that in the landmark group (100% vs. 88.1%, P 〈0.000 and 98.6% vs. 38.4%, P 〈0.000). Average access time in the ultrasound group was shorter than that in the landmark group ((6.3+13.6) seconds; interquartile range (4-62) seconds vs. (44.5+129.5) seconds; interquartile range (5-986) seconds). The complication rate in the ultrasound group was significantly lower than that in the landmark group (0.3% vs. 8.3%, P 〈0.000). Conclusion Compared with the landmark-guided approach, ultrasound-guided cannulation of the right IJV significantly improves success rate, decreases access time and reduces complication rate during establishment of peripheral CPB in robotic cardiac surgery. Background Robotic assisted minimally invasive cardiac sugery is a new technique that uses small port sites and peripheral vessel cannulation for cardiopulmonary bypass (CPB) has been used. The right internal jugular vein (IJV) is commonly used for intraoperative venous access to the central circulation and identified with an external landmark. Previous studies have demonstrated the superiority of ultrasound guidance over external landmark technique in anaesthetic and intensive care settings. The aim of the present study was to delineate the utility of ultrasound-guided cannulation of the IJV during establishment of peripheral CPB in robotic cardiac surgery. Methods We prospectively studied 296 adult patients undergoing ultrasound-guided right IJV cannulation during establishment of peripheral CPB in robotic cardiac surgery at our institute from January 2007 to October 2012 (ultrasound group). The success rate, the first attempt success rate, access time and the complication rate of ultrasound-guided method were compared with the landmark-guided method used for 302 historical control patients (landmark group). Results In the ultrasound group, 296 consecutive adult patients underwent ultrasound-guided right IJV cannulation during establishment of peripheral CPB in robotic cardiac surgery. In the landmark group, 302 patients underwent right IJV cannulation using the landmark-guided technique. The success rate and the first attempt success rate in the ultrasound group were significantly higher than that in the landmark group (100% vs. 88.1%, P 〈0.000 and 98.6% vs. 38.4%, P 〈0.000). Average access time in the ultrasound group was shorter than that in the landmark group ((6.3+13.6) seconds; interquartile range (4-62) seconds vs. (44.5+129.5) seconds; interquartile range (5-986) seconds). The complication rate in the ultrasound group was significantly lower than that in the landmark group (0.3% vs. 8.3%, P 〈0.000). Conclusion Compared with the landmark-guided approach, ultrasound-guided cannulation of the right IJV significantly improves success rate, decreases access time and reduces complication rate during establishment of peripheral CPB in robotic cardiac surgery.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第13期2414-2417,共4页 中华医学杂志(英文版)
关键词 ULTRASONOGRAPHY INTERVENTIONAL central venous minimally invasive surgical procedures robotic cardiac surgery cardiopuImonary bypass ultrasonography interventional central venous," minimally invasive surgical procedures robotic cardiac surgery, cardiopuImonary bypass
  • 相关文献

参考文献24

  • 1Modi P, Rodriguez E, Chitwood WR Jr. Robot assisted cardiac surgery. Interact Cardiovasc Thorac Surg 2009; 9: 500-555.
  • 2Left JD, Enriquez LJ. Robotic assisted cardiac surgery, lnt Anesthesiol Clin 2012; 50: 78-89.
  • 3Mohr FW, Falk V, Diegeler A, Walther T, Gummert JF, Bucerius J, et al. Computer enhanced "robotic" cardiac surgery: experience in 148 patients. J Thorac Cardiovasc Surg 2001; 121: 842-853.
  • 4Dawood MY, Lehr E J, de Biasi A, Haque R, Grigore A, Griffith BP, et al. Robotically assisted coronary endarterectomy. Innovations (Phila) 2011; 6: 391-394.
  • 5Schilling J, Engel AM, Hassan M, Smith JM. Robotic excision of atrial myxoma. J Card Surg 2012; 27: 423-426.
  • 6Gao CQ, Yang M, Xiao CS, Wang G, Wu Y, Wang JL. Robotically assisted mitral valve replacement. J Thorac Cardiovasc Surg 2012; 143 (4 Suppl): S64-S67.
  • 7Sutter FP, Berry T, Wertan MC. Precision incision: robotic coronary revascularization via 3.9 cm minithoracotomy. Innovations (Phila) 2012; 7: 223-228.
  • 8Sobieski MA 2rid, Slaughter MS, Hart DE, Pappas PS, Tatooles AJ. Peripheral cardiopulmonary bypass with modified assisted venous drainage and transthoracic aortic crossclamp: optimal management for robotic mitral valve repair. Perfusion 2003; 18: 307-311.
  • 9Troianos CA, Jobes DR, Ellison N. Ultrasound guided cannulation of the internal jugular vein. A prospective randomized study. Anesth Analg 1991; 72: 823-826.
  • 10Troianos CA, Hartman GS, Glas KE, Skubas N J, Eberhardt RT, Walker JD, et al. Guidelines for Performing Ultrasound Guided Vascular Cannulation: Recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr 2011; 24:1291-1318.