以某通信运营商通信枢纽楼低压配电系统改造项目为例,详细介绍了通信负荷的分类,包括一般负荷以及保障负荷,并说明了近期及远期负荷的估算方法,最后针对估算出的枢纽楼近远期的通信负荷,提出了合理的低压配电改造方案,解决了枢纽楼存在的问题。同时详细介绍了低压配电设备的使用及选型,其中包括低压配电柜、低压断路器、浪涌保护器,无功补偿装置等设备,为方案的具体实施提供了可靠依据。
With the distribution system reconstruction project of certain communications operator' s telecommunication hub building as an example, the classifications of communication load are described, including ordinary load and guaranteed load, and the methods to estimate the short-and long-term load expounded. Then according to the load estimation, reasonable reconstruction project for low-voltage distribution is proposed, thus to solve the problems in the construction of hub building. Meanwhile, the use and selection of low-voltage distribution devices is discussed, these devices include low-voltage distribution boards, low-voltage circuit breaker, surge protector, reactive power compensation device and so on, thus providing a reliable basis for the project implementation.
出处
《通信技术》
2013年第7期132-134,共3页
Communications Technology
关键词
通信枢纽楼
低压配电系统设计
低压配电设备
telecommunication hub building
distribution system design
Low-voltage distribution device