摘要 Lipoic acid (LA) has received great attention in the area of gold surface functionalization. In this study, LA was employed as a linker for the attachment of antibody to the gold surface of surface plasmon resonance (SPR) chip. By using this chip in a homemade SPR immunosensor, low molecular weight compound 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) can be detected at a low level of 0.01 ng/mL. There is a good linear relationship(R2 =0.943 1) between the results of SPR biosensor and enzyme-linked immunosorbent assay(ELISA). Lipoic acid (LA) has received great attention in the area of gold surface functionalization. In this study, LA was employed as a linker for the attachment of antibody to the gold surface of surface plasmon resonance (SPR) chip. By using this chip in a homemade SPR immunosensor, low molecular weight compound 2,3,7,8- tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) can be detected at a low level of 0.01 ng/mL. There is a good linear relationship (R2 = 0.943 1) between the results of SPR biosensor and enzyme-linked immunosorbent assay (ELISA).
出处 《Transactions of Tianjin University》 EI CAS 2013年第4期248-254,共7页 天津大学学报(英文版)
基金 Supported by the National Natural Science Foundation of Tianjin (No. 09JCZDJC25700, 12JCZDJC29600 and KJXH2011-11)
  • 相关文献

参考文献1

二级参考文献2

共引文献5

同被引文献41

  • 1Homola J, Yee S S, Gauglitz G. Surface plasmon resonance sensors: Review [J]. Sensors and Actuators B: Chemical, 1999, 54(1):3-15.
  • 2Willets K A, Van Duyne R P. Localized surface plasmon resonance spectroscopy and sensing [J]. Annual Review of Physical Chemistry, 2007, 58: 267-297.
  • 3Mayer K M, Hafner J H. Localized surface plasmon resonance sensors [J]. Chemical Reviews, 2011, 111 (6) : 3828-3857.
  • 4Chung T, Lee S Y, Song E Yet al. Plasmonic nanostructures for nano-scale bio-sensing[J]. Sensors, 2011, 11 (11): 10907-10929.
  • 5Cao J, Sun T, Grattan K T. Gold nanorod-based localized surface plasmon resonance biosensors: A review[J]. Sensors and Actuators B: Chemical, 2014, 195: 332-351.
  • 6Anker J N, Hall W P, Lyandres O et al. Biosensing with plasmonic nanosensors [J]. Nature Materials, 2008, 7 (6) :442-453.
  • 7Hutter E, Fendler J H. Exploitation of localized surface plasmon resonance [J]. Advanced Materials, 2004, 16(19): 1685-1706.
  • 8Raphael M P, Christodoulides J A, Delehanty J B et al. Quantitative LSPR imaging for biosensing with single nanostructure resolution[J]. Biophysical Journal, 2013, 104(1): 30-36.
  • 9Blaber M G, Henry A I, Bingham J Met al. LSPR imaging of silver triangular nanoprisms: correlating scattering with structure using electrodynamics for plasmon lifetime analysis [J]. The Journal of Physical Chemistry C, 2011, 116(1): 393-403.
  • 10Zhou W, Ma Y, Yang Het al. A label-free biosensor based on silver nanoparticles array for clinical detection of serum p53 in head and neck squamous cell carcinoma [J] . International Journal of Nanomedicine, 2011, 6 (1) : 381- 386.

引证文献1