摘要 为完善嵌入温场型温度记录仪相关的实验室校准方法,针对目前其校准方法存在的问题,分析它的测量原理和实际工作环境,按照使用手册和现有检定规程,提出将记录仪置于可接受的不同的工作环境温度下进行校准的方法,并且按照提出的校准方法完成了实验和数据分析。实验结论证明了所提出的嵌入温场型温度记录仪校准方法的正确性和必要性。 In order to promote the relevant calibration mthods for the embedded temperature field recorder, and overcome the problem existing in the present calibration methods, this paper analyzed the principle of measurement and the actual working environment, and put forward the calibration method which can put the calibrating recorder in different and acceptable temperature working environment according to the user manual and the verification regulation. The calibration experiment was completed in accordance with the proposed calibration method, and the experimental data were analyzed. The experimental results proven that the calibration method of embedded temperature field recorder is correct and necessary.
出处 《中国测试》 CAS 北大核心 2013年第3期24-26,56,共4页 China Measurement & Test
关键词 热处理炉 温度监测 嵌入温场型温度记录仪 测量原理 校准方法 heat treatment furnace temperature monitoring embedded temperature fieldrecorder measurement principle calibration method
  • 相关文献

参考文献10

二级参考文献13

  • 1Mark D. Bethea, Bruce N. Rosenthal. An Automated Themocouple Calibration System. IEEE[J].Transactions on Instrumentation and Measurement, 1992, 41 (5) :702-706.
  • 2王小科,吕双.C#从入门到精通[M].北京:清华大学出版社,2005:105-120.
  • 3JJF1178-2007用于标准铂电阻温度计的固定点装置校准规范[S].北京:中国计量出版社,2007.
  • 4JJG160--2007标准铂电阻温度计[S].北京:中国计量出版社,2007.
  • 5JJG229--1998工业铂、铜热电阻[s].北京:中国计量出版社,1998.
  • 6JJF1257--2010干体式温度校准器校准方法[S].北京:中国计量出版社,2010.
  • 7全国温度计量委员会.JJF1101-2003[S].北京:中国计量出版社,2003.
  • 8吕漫丽,孙灵芳.多传感器信息融合技术[J].自动化技术与应用,2008,27(2):79-82. 被引量:18
  • 9徐长春.高压灭菌锅的使用[J].中国医学装备,2008,5(4):24-26. 被引量:7
  • 10吴疆,吴方,王莉.精密短型铂电阻温度计的校准问题讨论[J].计测技术,2008,28(2):58-59. 被引量:1