摘要
为完善嵌入温场型温度记录仪相关的实验室校准方法,针对目前其校准方法存在的问题,分析它的测量原理和实际工作环境,按照使用手册和现有检定规程,提出将记录仪置于可接受的不同的工作环境温度下进行校准的方法,并且按照提出的校准方法完成了实验和数据分析。实验结论证明了所提出的嵌入温场型温度记录仪校准方法的正确性和必要性。
In order to promote the relevant calibration mthods for the embedded temperature field recorder, and overcome the problem existing in the present calibration methods, this paper analyzed the principle of measurement and the actual working environment, and put forward the calibration method which can put the calibrating recorder in different and acceptable temperature working environment according to the user manual and the verification regulation. The calibration experiment was completed in accordance with the proposed calibration method, and the experimental data were analyzed. The experimental results proven that the calibration method of embedded temperature field recorder is correct and necessary.
出处
《中国测试》
CAS
北大核心
2013年第3期24-26,56,共4页
China Measurement & Test
关键词
热处理炉
温度监测
嵌入温场型温度记录仪
测量原理
校准方法
heat treatment furnace
temperature monitoring
embedded temperature fieldrecorder
measurement principle
calibration method