期刊文献+

无机房电梯限速器-安全钳联动试验方法探讨 被引量:3

Research on the Governor and Safety Gear Linkage Test of Room-less Elevator
下载PDF
导出
摘要 在电梯检查过程中,需要进行限速器一安全钳联动试验。无机房电梯由于结构本身的特殊性和标准、规范的专门规定,导致许多检查人员对限速器一安全钳联动试验不熟练,甚至不会操作。针对该问题,在介绍相关规定的基础上,以三菱ELENESSA无机房电梯为例,探讨无机房电梯限速器-安全钳联动试验的方法,并总结了试验中需要注意的问题。 Governor and safety gear linkage test is necessary in the inspection of room-less elevator. However, quite a few inspectors even do not know the correct method to do this test because of the special structure and consequently the special rules for room-less elevator. According to this, the relative testing rules is introduced in this paper, and then a method to do the test is explained by take Mitsubishi ELENESSA room-less elevator as example. The key points during the test are summarized.
作者 冯双昌 吴昊
出处 《机电一体化》 2013年第6期40-42,共3页 Mechatronics
关键词 无机房电梯 限速器 安全钳 联动试验 room-less elevator governor safety gear linkage test
  • 相关文献

参考文献4

  • 1全国电梯标准化技术委员会.GB/T7024-2008电梯、自动扶梯、自动人行道术语[S].北京:中国标准出版社,2009.
  • 2全国电梯标准化技术委员会.GB7588-2003电梯制造与安装安全规范[S].北京:中国标准出版社.2003.
  • 3中国特种设备检测研究院.TSGT7001-2009电梯监督检验与定期检验规则-曳引与强制驱动电梯[S].北京:新华出版社,2010.
  • 4朱昌明,孙立新,张晓峰,等.电梯制造与安装安全规范解读[M].北京:中国标准出版社,2007.

共引文献9

同被引文献10

引证文献3

二级引证文献5