期刊文献+

CBCT在盆腔肿瘤放疗摆位中的临床应用 被引量:8

Clinical application of CBCT in radiotherapy for pelvic tumor
下载PDF
导出
摘要 目的应用Vrian Trilogy锥形束CT(CBCT)分析盆腔部调强放射治疗中的摆位误差,为设计放疗临床靶区(CTV)外放到计划靶区(PTV)提供数据参考。方法 30例盆腔肿瘤患者均采用调强放疗技术,真空袋固定,首次治疗均需行CBCT扫描,以后每周扫描1次,将CBCT图像和计划CT图像进行自动及手动匹配,获得X(左右)、Y(头脚)、Z(前后)方向的偏移数据,以判断摆位的准确性。结果患者首次摆位后行CBCT扫描,其在X、Y、Z方向上的误差分别为(1.73±0.62)mm、(5.63±0.13)mm、(2.81±0.52)mm;经纠正后的误差明显降低,且与首次摆位后的误差相比,有统计学意义(P<0.05);但在治疗过程中的再次摆位误差较纠正后显著增加(P<0.05);根据MPTV的计算公式(M=2.5∑总+0.7总σ),纠正前X、Y、Z方向的MPTV分别为4.58 mm、11.82 mm、6.45 mm,纠正后X、Y、Z方向的MPTV分别为1.78 mm、2.84 mm、2.14 mm。结论使用CBCT扫描系统,能较准确、高效地修正摆位误差,提高治疗精确度,并为治疗单位准确设定计划靶体积(PTV)提供了依据。 Objective Application of Vrian Trilogy linear accelerator cone beam CT positioning error analysis pelvic IMRT, provides reference data for the design of radiotherapy plan CTV into PTV. Methods A total of 30 cases of pelvic tumor were treated with IMRT, vacuum bag, the,first treatment were performed CBCT scanning, a week after the scan 1 times, the CBCT image and CT image automatic and manual matching, X (left-right), Y (cranio-caudal), Z (ven- tro-dorsal) data offset direction in order to judge, accuracy of positioning. Results Patients with a first positioning were scanned by CBCT, the X, Y, Z direction of the errors were (1.73±0.62)mm、(5.63±0.13)mm、(2.81±0.52)mm; the error corrected significantly decreased, compared with the first swing error bits, with statistical significance(P 〈 0.05); but in the course of treatment of the position error is corrected again increased significantly (P 〈 0.05); according to the calculation formula of MPTV (M=2.5 ∑ total+0.7σ), X, Y, Z before correction direction of MPTV were 4.58 mm, 11.82 mm, 6.45 mm, X, Y, corrected Z direction MPTV respectively 1.78 mm, 2.84 mm, 2.14 mm. Conclusion The use of CBCT scanning system, can accurately, efficiently correct positioning errors, improve the treatment accuracy, and for the treatment of unit set exactly planned target volume (PTV) provides a basis.
出处 《中国现代医生》 2013年第22期35-36,39,共3页 China Modern Doctor
基金 广东省佛山市卫生局医学科研立项课题(2011037)
关键词 CBCT 调强放疗 计划靶体积 摆位误差 CBCT Intensity-modulated radiotherapy Planning target volume Set-up error
  • 相关文献

参考文献13

  • 1胡逸民.调强放射治疗的最新进展[J].中国医疗器械信息,2005,11(2):1-5. 被引量:14
  • 2VanHaaren PM, Bel A, Hofman P,et al. Influence of daily setup measurements and corrections on the estimated delivered dose during IMRT treatment of prostate cancer patients[J]. Radiother Oncol,2009, 90(3) :291-298.
  • 3Meyer J,Wilbert J,Baier K,et al. Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treat- ment table[J]. Int J Radiat Oncol Biol Phys,2007,67:1220-1228.
  • 4van Herk M,Ploeger L,Sonke JJ. A novel method for megavoltage scatter correction in cone-beam CT acquired concurrent with rotational irradiation[J]. Radiother Oncol,2011,100(13) :365-369.
  • 5Gallagher MJ,Brereton HD ,Rostock RA,et al. A prospective study of treatment techniques to minimize the volume of pelvic small bowel with reduction of acute and late effects associated with pelvic irradiation[J]. Int J Radiat Oncol Biol Phys, 1986,12:1565-1573.
  • 6Green N. The avoidance of small intestine injury in gynecologic cancer[J]. Int J Radiat Oncol Biol Phys, 1983,9:1385-1390.
  • 7Montana GS, Fowler WC. Carcinoma of the cervix: analysis of bladder and rectal radiation dose and complications[J]. Int J Radiat Oncol Biol Phys, 1989,16:95-100.
  • 8Perez C,Grigsby P,Lockett M,et al. Radiation therapy morbidity in carcinoma of the uterine cervix:dosimetric and clinical correlation[J]. Int J Radiat Oncol Biol Phys, 1999,44:855-866.
  • 9Ahmad R,Hoogeman MS,Quint Set al. Interfraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner[J]. Radiother Oncol, 2008,89:172-179.
  • 10Siddiqui F,Shi C ,Papanikolaou N,et al. Image-guidance protocol comparison: supine and prone setup accuracy for pelvic radiation therapy[J]. Acta Oncol,2008,47:1344-1350.

共引文献13

同被引文献59

  • 1胡逸民.调强放射治疗的最新进展[J].中国医疗器械信息,2005,11(2):1-5. 被引量:14
  • 2庞学利,肖红,李建军,谭崇富,王希,曾勇,邓鹏,江湛.KV-X线CBCT用于鼻咽癌调强放疗精度保证的探讨[J].重庆医学,2007,36(20):2055-2056. 被引量:11
  • 3Bijhold J, Van Herk M, Vijlbrief R, et al.Fast evaluation of patient setup during radiotherapy by aligning features in portal and simulator images [J].Phys Med Biol, 1991,36( 12): 1665-1679.
  • 4Mackie TR, Kapatoes J, Ruchala K, et al. Image guidance for percise conformal radiotherapy[J].Int J Radiat Oncol Biol Phys, 2013, 56(1):89-105.
  • 5Havrilesky LJ, Kulasingam SL, Matchar DB, et al. FDG-PET for management of cervical and ovarian cancer[J]. Gynecol Oncol, 2005, 97(1): 183-191.
  • 6于金明,袁双虎.图像引导放射治疗研究及其发展[J].中华肿瘤杂志,2010,7( 12) :214-215.
  • 7Brahme A.treatment optimization using physical and radiobiologicalobjective functions: In Smith AR ( ed) Radiation therapy Phsics[M] .Springer Verlog,1995:209.
  • 8Stroom JC,de Boer JC,Hujzenga H,et al.Inclusion of geometricaluncertainties radiotherapy treatment planning by means of coverageprobability [ J ]. Int J RadiatOncolBiol Phys, 1999,43 ( 4) : 905-919.
  • 9van Heric M, Reneijer P, Lebesque JV. Inclusion of geometricuncertainties in treatment plan evaluation [ J ]. Int JRadiatOncolBiol Phys,2002, 52(5) :1407-1422.
  • 10Hong TS,Tome WA,ChapPell RJ,et al. The impact of daily setupvariations on head and neck intensity modulated radiation therapy[J].Int J Radiaoncol boil phys 2005,61(3) :779-800.

引证文献8

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部