在构件试验的基础上 ,对以ALC板为底板的迭合楼板的基本性能 ,如正截面强度计算、迭合面强度计算、抗裂度验算、使用荷载下的变形性能以及合理的构造措施等方面问题进行了探讨和研究。
On the base of experiments,this paper inquired and studied some problems on composite slab which used ALC slab as it's base slab.These problems included the ultimate moment capacity,the shear strength at the interface,the check compute method of crack resistivity,deformation at service load,and the reasonable construction measure for composite slab.
出处
《工业建筑》
CSCD
北大核心
2000年第10期49-51,共3页
Industrial Construction
基金
南京市建委科研基金
关键词
蒸压加气混凝土板
迭合楼板
迭合面
autoclaved lightweight aerated concrete slab\ composite slab\ interface