摘要
采用单因素试验方法,用芬顿试剂对粉煤灰基混凝剂吸附后的甲氰菊酯农药废水做进一步处理,以探讨新的甲氰菊酯农药废水处理技术,并确定芬顿试剂处理的最佳条件。结果表明,在甲氰菊酯农药废水pH为4、30%(质量分数)H2O2用量为15 mL/L、FeSO4.7H2O用量为2.0 g/L、温度为50℃、反应时间为60 min时,芬顿试剂处理效果最佳,此条件下CODCr去除率达95.78%。
Fenpropathrin wastewater was treated with Fenton reagent after absorption of fly ash coagulant. Single factor tests was applied to explore a new treatment techology for fenpropathrin wastewater and to optimize the conditions for Fenton treat- ment. The optimal experimental conditions were dtermined as follows, pH, 4; dosage of 30%(mass fraction) hydrogen perox- ide, 15 mL/L; dose of FeSO4 7H2O, 2.0 g/L; reaction temperature, 50 ℃; reaction time, 60 min. Under these conditions, the removal rate of wastewater CODCr reached up to 95.78%.
出处
《湖北农业科学》
北大核心
2013年第13期3031-3032,3037,共3页
Hubei Agricultural Sciences
基金
全国化工高等教育科学研究"十一五"规划立项课题(中化教协会〔2007〕003-33)
淮海工学院自然科学校内课题(KX11133)
2012年度淮海工学院大学生创新训练项目(2012-32)
关键词
芬顿试剂
甲氰菊酯
废水处理
Fenton reagent
fenpropathrin
wastewater treatment