期刊文献+

Arcing Model of a Disconnector and its Effect on VFTO 被引量:6

Arcing Model of a Disconnector and its Effect on VFTO
下载PDF
导出
摘要 In the computational process of very fast transient over-voltage (VFTO), it is essen-tial to find an accurate model for a gas insulated substation. The arcing model of the disconnector is particularly important. The general arcing model is not able to give a good description of the arc development process. In this paper, based on the physical process of arcing and existing arc models (the exponential time-varying resistance model and the segmental arcing models), a dy- namic arcing model is proposed, which is divided into two stages before and after the zero crossing. The dynamic arcing model combines hyperbola time-varying resistance and the Mayr model to describe the dynamic process of arcing. The present paper creates an arc model blockset upon the Matlab/Simulink software platform. Moreover for a specific 1100 kV station, VFTO is simulated in detail based on different arcing models. It is demonstrated that the dynamic arcing model can describe the physical arc process precisely and is useful for improving the accuracy of VFTO simulations. In the computational process of very fast transient over-voltage (VFTO), it is essen-tial to find an accurate model for a gas insulated substation. The arcing model of the disconnector is particularly important. The general arcing model is not able to give a good description of the arc development process. In this paper, based on the physical process of arcing and existing arc models (the exponential time-varying resistance model and the segmental arcing models), a dy- namic arcing model is proposed, which is divided into two stages before and after the zero crossing. The dynamic arcing model combines hyperbola time-varying resistance and the Mayr model to describe the dynamic process of arcing. The present paper creates an arc model blockset upon the Matlab/Simulink software platform. Moreover for a specific 1100 kV station, VFTO is simulated in detail based on different arcing models. It is demonstrated that the dynamic arcing model can describe the physical arc process precisely and is useful for improving the accuracy of VFTO simulations.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第7期644-647,共4页 等离子体科学和技术(英文版)
基金 supported by Special Research Fund for Doctoral Program of Education Ministry of China (No. 20092102110001) Natural Science Foundation of Liaoning Province of China (No. 201102169) National Natural Science Foundation of China (No. 51277123)
关键词 disconnector switching UHV dynamic arcing model gas insulated substa-tion VFTO disconnector switching, UHV, dynamic arcing model, gas insulated substa-tion, VFTO
  • 相关文献

参考文献16

  • 1Yue Gongchang, Liu Weidong, Chen Weijiang et al. 2011, Proceedings of CSEE, 31: 18 (in Chinese).
  • 2Chen Weijiang, Li Zhibing, Sun Gang, et al. 2011, Pro?ceedings of CSEE, 31: 38 (in Chinese).
  • 3Yamagata Y, Tanaka K. 1996, IEEE Transaction on Power Delivery, 11: 872.
  • 4Meng Tao, Lin Xin, Xu Jianyuan. 2010, Transactions of China Electrotechnical Society, 25: 69 (in Chinese).
  • 5Kumar V V, Thomas J M, Naidu M S. 2001, IEEE Transaction on Power Delivery, 16: 539.
  • 6Qian Jiali. 1999, High-voltage switch opening and clos?ing the small capacitive current and inductor current. China Electric Power Press, Beijing (in Chinese).
  • 7Shi Baozhuang, Li Zhimin, Zhang Wenyuan, et al. 1998, Power System Technology, 22: 1 (in Chinese).
  • 8Ma Guoming, Li Chengrong, Quan Jiangtao, et al. 2010, Proceedings of the CSEE, 30: 122 (in Chinese).
  • 9Ruan Quanrong, Shi Wei. 2005, High Voltage Engi?neering, 31: 7 (in Chinese).
  • 10Lin Xin, Meng Tao, Xu Jianyuan, et al. 2009, High Voltage Engineering, 23: 61 (in Chinese).