期刊文献+

一种六自由度上肢康复机器人的结构设计及运动学分析 被引量:9

Structure design and analysis of kinematics of a 6-DOF upper-limbed rehabilitation robot
下载PDF
导出
摘要 为解决现有上肢康复机器人功能单一以及结构复杂的问题,提出了一种6-DOF外骨骼式上肢康复机器人,建立了康复机器人的运动学模型,通过D-H变换对其正向运动学和逆向运动学进行求解.运用Pro/E对康复机器人进行三维建模,通过Mechanism/Pro导入ADAMS/view中进行运动学仿真,得到机器人末端位移的仿真曲线和理论曲线一致,验证了理论推导的正确性,进一步仿真结果证明该方案具有较好的运动特性. In order to solve the problems that the exiting upper-limbed rehabilitation robot has sole function and complicated structure, a 6-DOF exoskeleton upper-limbed rehabilitation robot is put forward according to the structure of upper limb of the human body. The kinematics model of the rehabilitation robot was established, and kinematics positive and inverse solutions were solved by D-H transformation. Three dimensional model of the rehabilitation robot was created by Pro/E and was imported into ADAMS/view for the kinematics simulation by Mechanism/Pro. The obtained simulation position curves are consistent with the theoretical position curves, verif- ying the correctness of the theoretical derivation. Further results of the simulation proves the smooth movement characteristics of the scheme.
出处 《工程设计学报》 CSCD 北大核心 2013年第4期338-343,共6页 Chinese Journal of Engineering Design
基金 国家自然科学基金资助项目(50905077) 教育部高校博士点基金SRFDP资助项目(20093227120007) 江苏省博士后基金资助项目(0901010B)
关键词 外骨骼 康复机器人 运动学 仿真 exoskeleton rehabilitation robot~ kinematics~ simulation
  • 相关文献

参考文献1

二级参考文献20

  • 1[1]DARIO P, GUGLIELMELLI E, LASCHI C. Humanoids and personal robots: Design and experiments [ J ] . Journal of Robotic Systems, 2001,18 (12): 673 - 690.
  • 2[4]TSUJI L T. Pattern classification of time-series EMG signals using neural networks [ J ]. International Journal of Adaptive Control and Signal Processing, 2000, 14:829 -848.
  • 3[5]LATERZ F. Analysis of EMG signals by means of the matched wavelet transform [ J ]. Electronics Letters,1997,5:357 - 359.
  • 4[7]MORIN E L. Identifying the EMG- force relationship [ J]. IEEE EMBC and CMBEC, 1995,2:1397 - 1398.
  • 5[8]CLANCY E A. Relating agonist - antagonist electromyograms to joint torque during isometric, quasi-isotonic,nonfatiguing contractions [ J ]. IEEE-Trans Bioned Eng,1997,44(10): 1024 - 1028.
  • 6[9]MATHIEU P A. EMG and Kinematics of normal subjets performing trunk flexion/extensions freely in space [ J ].Journal of Electromyography and Kinesiology, 2000, 10(3): 197 -209.
  • 7[10]LUH J J. Using time-varying autogressive filter to improve EMG amplitude estimator[J]. IEEE- EMBC and CMBEC, 1995, 2:1343 - 1344.
  • 8[11]KERMANI M Z. EMG featureselection for movement control of a cybenetic arm. Cybernetics and Systems [ J ]. An International Journal, 1995,26:189 - 210.
  • 9[12]YANAETAL K. Surface electromyogram recruitment analysis using higher order spectrum[J]. IEEE -EMBC and CMBEC, 1995,2:1345 - 1346.
  • 10[13]ZAHEDI E. Graphical simulation of artificial hand motion with fuzzy EMG pattern recognition [ A ]. Proceedings RC IEEE- EMBC&14THBMESI[C]. [s.l.]: [ s.n.], 1995.

共引文献44

同被引文献86

引证文献9

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部