摘要
目的:通过对高频手术设备检测仪的临床应用,加强高频手术设备的临床使用安全。方法:使用高频手术设备检测仪对相关设备进行质量安全检测。结果:高频手术设备技术参数的稳定性和重复性检测均符合要求,但输出特性发生了偏移。结论:高频手术设备属于临床应用的高风险设备,为了保证高频手术设备的使用安全,必须使用高频手术设备检测仪对其进行定期检测,以保证其技术参数的稳定、可靠,还应建立健全质量安全检测制度,以便对高频手术设备的安全性进行有效控制。
Objective To apply the detector for high-frequency surgery equipment to enhance its usage safety.Methods The quality safety detection of high-frequency surgery equipment was performed with the detector.Results The stability and repeatability of the technical parameters of the high-frequency surgery equipment complied with the standard,while the shift occurred for the output characteristic.Conclusion The detector and quality safety detection regulation have to be involved in the quality assurance of the high-frequency surgery equipment.
出处
《医疗卫生装备》
CAS
2013年第7期108-110,共3页
Chinese Medical Equipment Journal
关键词
高频手术设备
检测仪
质量控制
安全检测
高风险设备
high-frequency surgery equipment
detector
quality control
safety detection
high-risk equipment