期刊文献+

铁氰化铈薄膜固载血红蛋白修饰的过氧化氢生物传感器的制备及性能 被引量:1

Preparation and performance of glassy carbon electrode modified by cerium ferricyanide film with immobilized hemoglobin as hydrogen peroxide biosensor
下载PDF
导出
摘要 采用电化学沉积法将铁氰化铈(CeHCF)薄膜修饰于玻碳电极(GCE)表面,得到铁氰化铈薄膜修饰玻碳电极;将血红蛋白(Hb)固载于该修饰电极表面,成功制得了Hb/CeHCF/GCE过氧化氢生物传感器.考察了铁氰化铈薄膜修饰玻碳电极的氧化还原机理和制备条件,并对血红蛋白在电极上的电子传递过程进行了较为深入的研究.结果表明,铁氰化铈薄膜为血红蛋白提供了温和的固载环境,可实现血红蛋白与电极表面的直接电子转移,提高了血红蛋白的电化学活性;所制得的传感器对过氧化氢具有较高的催化响应和较强的稳定性.相关研究结果在生物医学和临床医学领域具有一定的借鉴意义. Cerium ferricyanide film(CeHCF)was electrochemically deposited onto the surface of glassy carbon electrode(GCE)to afford GCE modified by CeHCF.Onto the surface of CeHCF-modified GCE was then immobilized hemoglobin(Hb)to provide Hb/CeHCF/GCE as a hydrogen peroxide biosensor.The oxidation-reduction mechanisms of the CeHCF-modified GCE and the experimental conditions for preparing this modified GCE were examined;and the electron transfer process of Hb on the surface of the modified GCE was investigated.Results show that cerium ferricyanide film provides a gentle immobility environment for hemoglobin thereby realizing the direct electron transfer between Hb and the electrode as well as improving the electrochemical activity of Hb.As-fabricated Hb/CeHCF/GCE exhibits good catalytic response to hydrogen peroxide and has good stability as well.Relevant research results may be of significance in the fields of biomedicine and clinical inspection.
出处 《化学研究》 CAS 2013年第4期387-393,共7页 Chemical Research
关键词 铁氰化铈薄膜 血红蛋白 玻碳电极 过氧化氢 生物传感器 制备 性能 cerium ferricyanide film hemoglobin glassy carbon electrode hydrogen peroxide biosensor preparation performance
  • 相关文献

参考文献14

  • 1PARK B W, YOON D Y, KIM D S. Recent progress in bio-sensing techniques with encapsulated enzymes[J]. Biosens Bioelectr, 2010, 26(1): 1-10.
  • 2JOHN H T L, KEITH B M, JEREMY D G. Biosensor technology: technology push versus market pull[J]. Biotechn Adv, 2008, 26(5): 492-500.
  • 3SERENA F, STEFANO B, LUCA R. Modulation of expression and polymerization of hemoglobin polytaur, a potential blood substitute[J]. Arch Biochem Biophys, 2011, 505(1): 42-47.
  • 4WANG Quan Lin, LU Gong Xuan, YANG Bao Jun. Direct electrochemistry and electrocatalysis of hemoglobin immobi- lized on carbon paste electrode by silica sol-gel film[J]. Biosens Bioelectr, 2004, 19(10) : 1269-1275.
  • 5SUN Wei, ZHAI Zi Qin, WANG Dan Dan. Electrochemistry of hemoglobin entrapped in a nafion/nano-zno film on carbon ionic liquid electrode[J]. Bioeleetrochemistry, 2009, 74(2): 295-300.
  • 6GHOSIA L, SYED A A, ATIYA A. Molecular mechanism of high altitude respiration: primary structure of a minor he- moglobin component from tufted duck(aythya fuligula, anseriformes)[J]. Bioehem Biophys Res Commun, 2004, 326(1) : 123- 130.
  • 7HARRY A S. pH effects on the binding of oxygen to non-vertebrate monomeric hemoglobins, a linked function modelrJ]. J Theoret Biology, 2004, 229(1): 113-118.
  • 8DAI Zhi Hui, LIU Song Qin, JU Huang Xian. Direct electron transfer and enzymatic activity of hemoglobin in a hexagonal mesoporous silica matrix[J]. Biosens Bioelectr, 2004, 19(8): 861-867.
  • 9史传国,衡姝婧,徐静娟,陈洪渊.基于血红蛋白/硒化镉量子点多层膜的H_2O_2生物传感器[J].无机化学学报,2009,25(9):1526-1531. 被引量:5
  • 10SHEETAL C, CHANDRA S P. An amperometric hemoglobin biosensor based on immobilization of fructosyl amino acid oxidase onto zinc oxide nanoparticles-polypyrrole film[J]. Anal Biochem, 2012, 430(2): 156-162. Actuat B: Chem, 2010, 148(1) : 253 -258.

二级参考文献34

  • 1Xiao Y,Ju H X,Chen H Y.Anal.Chim.Acta,1999,391:73-82.
  • 2Holt R E,Cotton T M.J.Am.Chem.Soc.,1989,111:2815-2821.
  • 3Decher G,Hong J D.MacromoL Chem.Macromol.Syrup.,1991,46:321-327.
  • 4Zhao W,Xu J J,Chen H Y.Electroanal.,2006,18:1737-1748.
  • 5Liu H,Rusling J F,Hu N.Langmuir,2004,20:10700-10705.
  • 6Liu H,Hu N.J.Phys.Chem.B,2005,109:10464-10473.
  • 7Xie Y,Liu H,Hu N.Bioelectrochem.,2007,70:311-319.
  • 8Zhang H,Liu H,Hu N.J.Phys.Chem.B,2006,110:2171-2179.
  • 9Shen L Hu N.Biomacromolecules,2005,6:1475-1483.
  • 10Zhao W,Xu J J,Chen H Y.Frontiers Biosci.,2005,10:1060-1069.

共引文献11

同被引文献30

  • 1时巧翠,王素芬.辣根过氧化物酶生物传感器的制备及其应用于过氧化氢的测定[J].理化检验(化学分册),2007,43(6):433-435. 被引量:5
  • 2Itaya K. ,Ataka T. ,Toshima S.. Spectroelectrochem- istry and electrochemical preparation method of Prus- sian blue modified electrodes [J]. J. Am. Chem. Soc. , 1982,104 ( 18 ) :4767 - 4772.
  • 3Zhang Y,Luo H Q,Li N B. Hydrogen peroxide sensor based on Prussian blue electrodeposited on (3 - mer- captopropyl) -trimethoxysilane polymer-modified gold electrode[J ]. Bioproc. Biosyst. Eng. , 2011,34 ( 2 ) : 215 -221.
  • 4Li H X, Ban Y P, Gao Q, et al. Hydrogen peroxide de- tection with n-silicon photoelectrodes modified by nickel hexacyanoferrate films [J]. Sci. Adv. Mater. ,2012,4 (9) :935 - 940.
  • 5Qin X ,Wang H C,Miao Z Y,et al. A novel non-en- zyme hydrogen peroxide sensor based on catalytic re- duction property of silver nanowires [J]. Talanta, 2015,139(2) :56 -61.
  • 6Wang Z D,Hao X G,Zhang Z L,et al. One-step uni- polar pulse electrodeposition of nickel hexacyanoferra- te/chitosan/carbon nanotubes film and its application in hydrogen peroxide sensor [J]. Sens. Actuators, B Chem. ,2012,162 ( 1 ) :353 - 360.
  • 7Biuck H, Mojtaba J. A novel nonenzymatic hydrogen peroxide sensor based on the synthesized mesoporous carbon and silver nanoparticles nanohybrid [J]. Sens. Actuators, B Chem. ,2014,203 (7) :919 - 925.
  • 8Li X Y,Liu X H,Wang W W,et al. High loading Pt nanoparticles on functionalization of carbon nanotubes for fabricating nonenzyme hydrogen peroxide sensor [J]. Biosens. Bioelectron. ,2014,59 ( 3 ) : 221 - 226.
  • 9Zhao W,Wang H,Qin X,et al. A novel nonenzymatic hydrogen peroxide sensor based on multi-wall carbon nanotube/silver nanoparticle nanohybrids modified gold electrode [J]. Talanta, 2009, 80 ( 2 ) : 1029 - 1033.
  • 10Xu J,Wei X W,Song X G,et al. Synthesis and elec- tro-catalytic activity of multi-walled carbon nanotubes/ Cu-Ag nanocomposites[J].J. Mater. Sci. ,2007,42 (16) :6972 -6976.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部