摘要
利用电化学方法在玻碳电极上均匀沉积亚微米粒度铂黑并进而修饰一层胆碱氧化酶膜,制成了胆碱酶电极。以计时电流法测定氯化胆碱,检测下限为 7.4 μmol/L,线性范围2.4×10-2~ 1.0 mmol/L,重现性好,使用寿命较长。
An enzyme for choline was fabricated by modifying an enzyme layer composing of choline oxidase on the surface of sub-micrometer platinum-black particles,which was electro-deposited on the surface of glassy carbon electrode. Chronoamperometry was applied for quantitative determination of choline. Experimental results indicated this enzyme electrode gave a wide linear detection from 2.4 ×10-2 to 1.0 mmol/L of choline and low detection limit of 7.4 μmol/L. The enzyme electrode was also reproducible and good for long-term use.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
2000年第9期1066-1069,共4页
Chinese Journal of Analytical Chemistry
基金
中国科学院重大项目(9002kj951-Al-507)
中国科学技术大学基地择优基金资助课题
关键词
胆碱
电化学生物传感器
酶电极
计时电流法
Choline
electrochemical biosensor
enzyme electrode
chronoamperometry