摘要
锂稀释法是一种新 的、目前正处于研究阶段的心排血量CO测定法。其操作过程为:从中心静脉注入氯化锂,然后在外周动脉处通过锂敏感探头测锂离子引起的电压变化,通过公式计算CO。结果表明,该法简单、安全、准确性高、价格便宜。本文就其作用原理、实验和临床研究、优缺点作一综述。
Lithium dilution technique is a
new method of measuring cardiac output. (CO) A bolus injection of lithiurm chloride is given via a central venous and arterial plasma (Li+) recorded using a specially developed sensor incorporating a Li+ selective electrode. CO is derived from the lithium dilution curve. Studies demonstrate that it's simple, reliable, safe and cheap. This article introduced its methods, principle, researches, advantages and shortcomings.
出处
《当代医学》
2000年第7期32-34,共3页
Contemporary Medicine
关键词
心排血量
锂稀释法
氯化锂
麻醉
cardiac output, lithium dilution, littium chloride