期刊文献+

时间-空间相关成像技术的反转模式在胎儿心血管成像中的应用进展

Application progresses of spatio-temporal image correlation with inversion mode in fetal cardiovascular imaging
下载PDF
导出
摘要 随着三维及四维超声技术的迅速发展,时间-空间相关成像技术(STIC)已成为研究胎儿心脏的一种相对成熟的技术,其多种成像模式可提供更多结构及血流的相关信息,为临床诊断提供依据。STIC技术的反转模式可更清晰、准确地呈现心室腔和血管腔的立体结构。本文就其在胎儿心血管系统中的研究进展进行综述。 With the rapid development of three-dimensional and four-dimensional ultrasound technology,spatio-temporal image correlation(STIC) technology has become a relatively mature technology for the study of fetal heart.Multiple imaging modes of STIC provide more relevant information about structure and blood flow,as well as the basis for clinical diagnosis.STIC technology with inversion mode can more clearly and accurately present the three-dimensional structure of ventricular chamber and vascular cavity.The progresses of its application in the fetal cardiovascular system were reviewed in this article.
出处 《中国介入影像与治疗学》 CSCD 2013年第7期434-437,共4页 Chinese Journal of Interventional Imaging and Therapy
基金 国家"十一五"科技支撑计划课题项目(2006BAI05A04)
关键词 胎儿心脏 产前诊断 时间-空间相关成像 反转模式 Fetal heart Prenatal diagnosis Spatio-temporal image correlation Inversion mode
  • 相关文献

参考文献26

  • 1Wieczorek A. Hernandez-RoblesJ. Ewing L. et al. Prediction of outcome of fetal congenital heart disease using a cardiovascular profile score. Ultrasound Obstet Gynecol , 2008.31(3) :284-288.
  • 2刘士龙,吴瑛.四维超声在胎儿先天性心脏病诊断中的应用与进展[J].中国介入影像与治疗学,2008,5(6):473-475. 被引量:12
  • 3Hata T. Dai SY. Inubashiri E. et al. Four-dimensional sonogra?phy with B-flow imaging and spatiotemporal image correlation for visualization of the fetal heart.J Clin Ultrasound. 2008.36(4): 204-207.
  • 4Fang FY. Hsing-I W. Chih-Yao C. et al. High-definition power Doppler ultrasound facilitates prenatal diagnosis of interrupted aortic arch.J Med Ultrasound. 2011.19(2) :61-63.
  • 5Hata T. Tanaka H. NoguchiJ. et al. Four-dimensional volume?rendered imaging of the fetal ventricular outflow tracts and great arteries using inversion mode for detection of congenital heart dis?ease.J Obstet Gynaecol Res. 2010.36(3) :513-518.
  • 6Lee W. Goncalves LF. Espinoza 1. et al. Inversion mode: A new volume analysis tool for 3-dimensional ultrasonography.J Ultra?sound Med. 2005.24(2):201-207.
  • 7AraujoJunior E. de Bussamra LC. Barros FS. et al. Prenatal di?agnosis of Ebstein's anomaly using spatio-temporal image correla?tion (STIC) and inversion mode. Arch Gynecol Obstet , 2008.278 (4) :387-391.
  • 8Goncalves LF. Lee W. Chaiworapongsa T. et al. Four-dimen?sional ultrasonography of the fetal heart with spatiotemporal im- age correlation. AmJ Obstet Gynecol , 2003,189(6):1792-1802.
  • 9Goncalves LF, Espinoza 1. Romero R, et al. Four-dimensional ultrasonography of the fetal heart using a novel tomographic ul?trasound imaging display.J Perinat Med, 2006,34(1): 39-55.
  • 10Yagel S, Cohen SM, Shapiro I, et al. 3D and 4D ultrasound in fetal cardiac scanning: A new look at the fetal heart. Ultrasound Obstet Gynecol, 2007,29(1):81-95.

二级参考文献32

  • 1[1]Kujak A,Vecek N,Hafner T,et al.Prenatal diagnosis:what does four-dimensional ultrasound add? Perinat Med,2002,30(1):57-62.
  • 2[2]Yagel S,Cohen SM,Shapiro I,et al.3D and 4D ultrasound in fetal cardiac scanning:a new look at the fetal heart.Ultrasound Obstet Gynecol,2007,29(1):81-95.
  • 3[3]Goncalves LF,Lee W,Chaiworapongsa T,et al.Four-dimensional-ultrasonography of the fetal heart with spatiotemporal im agecorrelation.Am J Obstet Gynecol,2003,189(6):1792-1802.
  • 4[4]Goncalves LF,Lee W,Espinoza J,et al.Examination of the fetal heart by four-dimensional (4D) ultrasound with spatiotemporal image correlation (STIC).Ultrasound Obstet Gynecol,2006,27(3):336-348.
  • 5[6]Espinoza J,Roberto R,Kusanovic JP,et al.The role of the view of the ductal arch in identification of fetuses with conotruncal anomalies using 4-dimensional ultrasonography.J Ultrasound Med,2007,26(9):1181-1188.
  • 6[7]Mayers SA,Fresquez M,Hamill N,et al.Four-dimensional sonography of the fetal heart with spatiotemporal image correlation directed at the interventricular septum.J Ultrasound Med,2007,26(8):1071-1075.
  • 7[8]Espinoza J,Kusanovic JP,Goncalves LF,et al.A novel algorithm for comprehensive fetal echocardiography using 4-dimensional ultrasonography and tomographic imaging.J Ultrasound Med,2006,25(8):947-956.
  • 8[9]Paladini D,Vassallo M,Sglavc G,et al.The role of spatio-temporal image correlation (STIC) with tomographic ultrasound imaging (TUI) in the sequential analysis of fetal congenital heart disease.Ultrasound Obstet Gynecol,2006,27(5):555-561.
  • 9[10]Sldansky MS,DeVore GR,Wong PC,et a1.Real-time dimensional fetal echocardiography with an instantaneous volume rendered display:early description and pictorial essay.J Ultrasound Med,2004,23(2):283-289.
  • 10[11]Yagel S,Benachi A,Bonnet D,et al.Rendering in fetal cardiac scanning:the intracardiac septa and the coronal atrioventricular valve planes.Ultrasound Obstet Gynecol,2006,28(3):266-274.

共引文献20