摘要
通过对两套大容量电火花震源系统进行激发声波测试,发现两者的频率有所差异。进而测试这两套系统的固体放电开关的放电电流,并对比放电电流及这两套设备的固体放电开关闸流管的电子特性,讨论固体放电开关对激发声波频的影响。
Through testing of acoustic wave generated by two high capacity sparker systems, the frequency differences between the two systems were found. Then testing the discharging current of solid discharge switch on the two sparker systems and comparing discharge current and electronic properties of the two solid discharge switch thyratrons, we discussed the effect of solid discharge switch to dominant frequency of generated acoustic wave.
出处
《南海地质研究》
2012年第1期39-48,共10页
Gresearch of Eological South China Sea
基金
国家“863”项目海洋技术领域大容量电火花震源的技术研究课题(2006AA09Z347)资助
关键词
电火花震源
声波
放电电流
固体放电开关
闸流管
Sparker Acoustic wave Discharge current Solid discharge switch Thyratron