人工全髋关节置换患者关节滑液中MCP-1和IL-8的表达水平及其与骨质溶解、关节磨损关系的探讨 被引量:1

The correlation of MCP-1 and IL-8 expression levels and osteolysis and wear particles in total hip arthroplasty
下载PDF
导出
摘要 目的研究人工全髋关节置换患者关节滑液中白介素8(IL-8)和单核细胞趋化蛋白1(MCP-1)的表达水平,探讨其与人工关节周围骨质溶解及关节磨损之间的相关性。方法酶联免疫吸附法(ELISA)检测15例陶瓷-陶瓷、16例金属-金属材质人工关节置换组和10例对照组中MCP-1和IL-8的表达水平,扫描电子显微镜和x-射线分析人工关节周围骨质溶解及磨损微粒的水平。结果与对照组相比,陶瓷-陶瓷及金属-金属人工关节置换患者关节滑液中大量表达MCP-1及IL-8,且金属-金属人工关节置换组关节滑液中MCP-1的水平明显高于陶瓷-陶瓷组;金属-金属组中有8例患者发生了骨质溶解,陶瓷-陶瓷组中未检测到骨质溶解;MCP-1与骨质溶解及关节磨损微粒之间相关性较差,而IL-8与骨质溶解及关节磨损微粒的产生存在一定的相关性。结论人工关节存在促使大量MCP-1及IL-8表达,且IL-8大量产生能引起金属-金属人工关节周围发生骨质溶解及产生磨损微粒,表明有可能通过触发炎症反应引起骨质溶解诱导的人工关节松动,提示具有作为人工关节松动标记物的潜力,同时为人工关节无菌性松动防治提供新的思路。 Objective To explore the expression levels of interleukin 8 (IL-8) and monocyte chemoattractant protein 1 (MCP-1) in the synovial fluid. In addition, the relationship between these two chemokines and osteolysis and wear particles resulted from repeated abrasion was studied after total hip arthroplasty. Methods The expression levels of MCP-1 and IL-8 in fifteen ceramic-on-ceramic (cer-cer), sixteen metal-on-metal (met-met) and ten control patients were detected by enzyme-linked immunosorbent assay (ELISA). The presence of wear particles in the synovial fluid and osteolysis were analyzed by scanning electron microscopy and energy dispersive X-ray spectroscopy. Results The MCP 1 and IL-8 levels in the synovial fluid of patients with cer-cer and met-met couplings were significantly higher than con- trols,and the expression levels of MCP-1 in met-met coupling was notably higher than cer-cer coupling. Only eight pa- tients with osteolysis were detected in met-met coupling,and'no osteolysis was found in patients with cer-cer coupling. Furthermore,a significant correlation was found between synovial fluid IL-8 levels and the area of osteolysis and the presence of wear particles in patients undergoing total hip arthroplasty. However,no obvious correlation was found be- tween MCP-1 levels and the area of osteolysis and the presence of wear particles. Conclusion The presence of the pros- thesis was responsible for an increase in the expression levels of MCP-1 and IL-8, and notably higher levels of IL-8 in met-met coupling resulted in area of osteolysis and the presence of wear particles. All of these results indicate that the chemokine can be related to osteolysis resulted from inflammatory reaction, and may be a useful aseptic loosening of hip prosthesis marker. What we did will open new opportunity in prevention of aseptic loosening of hip prosthesis.
机构地区 空军总医院骨科
出处 《中国实验诊断学》 2013年第7期1260-1263,共4页 Chinese Journal of Laboratory Diagnosis
关键词 人工全髋关节置换 MCP-1 IL-8 骨质溶解 关节磨损 total hip arthroplasty MCP-1 IL-8 osteolysis wear particles
  • 相关文献

参考文献12

  • 1曾凡营,张勇,刘文杰,王群,张连有.人工关节置换治疗高龄股骨粗隆间骨折临床效果分析[J].中国全科医学,2009,12(4):326-327. 被引量:19
  • 2邵敏.人工关节置换术治疗老年股骨颈骨折的疗效研究[J].中国骨与关节损伤杂志,2006,21(10):775-777. 被引量:38
  • 3Wooley P. , Schwarz E. , Aseptic loosening [J]. Gene therapy, 2004,11(4) :402.
  • 4Kevin J, Michael D. The impact of infection after total hip arthro- plasty on hospital and surgeon resource utilization[J]. The Jour- nal of I3one and Joint Surgery (American) ,2005,87(8) : 1746.
  • 5Maloney W, Smith R. Periprosthetic osteolysis in total hip arthro- plasty:the role of particulate wear debris[J]. Instructional course lectures, 1996,45,171.
  • 6Wang CT,l.in YT, Chiang BL, et al. Over expression of receptor activator of nuclear factor nB ligand (RANKL) ,inflammatory cy- tokines,and chemokines in periprosthetic osteolysis of loosened total hip arthroplasty[J]. Biomaterials, 2010,31 ( 1 ) : 77.
  • 7Tanaka R, Yasunaga Y, Hisatome T, et al. Serum interleukin 8 levels correlate with synovial fluid levels in patients with aseptic loosening of hip prosthesis[J]. The Journal of arthroplasty,2005, 20(8),1049.
  • 8施前锋,王叶萍,姚航平.类风湿关节炎患者血清及关节滑液RANTES和MCP-1的表达水平及其临床意义[J].现代中西医结合杂志,2008,17(22):3410-3412. 被引量:1
  • 9Ingham E. , Fisher J. , The role of macrophages in osteolysis of total joint replacement [J]. Biomaterials, 2005,26 ( 11 ), 1271.
  • 10Aroukatos P,Repanti M,Repantis T,et al. Immunologic adverse reaction associated with low-carbide metal-on-metal hearings in total hip arthroplasty[J]. Clinical Orthopaedics and Related Re- search, 2010,468(8) : 2135.

二级参考文献27

  • 1吴志斌,林国发,吴厚敏,扬挺.人工关节置换术治疗股骨颈骨折后骨不连[J].中国骨与关节损伤杂志,2005,20(1):54-55. 被引量:7
  • 2沈侠,沈建中,茆振华,姜其为,胡清潭.经皮空心加压螺纹子母钉治疗股骨颈骨折[J].中华骨科杂志,1995,15(3):139-141. 被引量:143
  • 3孙渊,赵金柱.动力加压髋螺钉内固定治疗股骨粗隆间骨折45例[J].疑难病杂志,2005,4(6):362-363. 被引量:1
  • 4胥少汀,葛宝丰,徐印坎.实用骨科学[M].3版.北京:人民军医出版社,2008:708.
  • 5Chen KC, Gurder SG. Cemented hemiarthroplasties for elderly patients with in tertrochanteris fractures [J]. Clin Orthop, 2000, 317 (2) : 206 -215.
  • 6Meding JB, Ritter MA, Keating EM, et al. Impaction bone grating before insertion of a femoral stem with cement in rervision total hip arthmpasty. A Minimum Two year follow up study[J]. J Bone Joint Surg (AM), 1997, 79, 1834-1841.
  • 7Arnlod WD,Lyden JP.Minkoff J.Treatment of intra-capsular fractures of the femoral neck.with special reference to percutaneous Knowles pinning.J Bone Joint Surg (Am),1974,56:2544
  • 8Beckenbaugh RD.Ilstrup DM.Total hip arthoplasty.A review of three hundred and thirty-three cases with long follow-up.J Bone Joint Surg (Am),1978,60 (3):3066
  • 9Stauffer RN.Ten-year follow-up study of total hip replacement with particular reference to roentgenographic loosening of the components.J Bone Joint Surg (Am),1982,64 (7):983
  • 10Galante J,Rostoker W,Lueck R,et al.Sintered fiber metal composites as a basis for attachment of implants to bone.J Bone Joint Surg (Am),1971,53:101

共引文献55

同被引文献2

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部