对V型滤池在运用过程中存在的问题进行了分析,提出了相应的解决思路,并对滤后水调节阀控制原理进行了研究试验,总结了适合晋城市的改造措施,经改造及试运行后,该滤池在无人值守的情况下安全经济运行,达到了预期目的。
The paper analyzes problems existing in the application of V-style filter tank,puts forward corresponding solving concept,experimentally studies control principles of water adjustment valve filtered,and summarized suitable improving measures.Through transformation and experimental implementation,the filter operation unattended is safe,which achieves predicted goal.
出处
《山西建筑》
2013年第24期148-149,共2页
Shanxi Architecture
关键词
滤池
PLC
电磁阀
filter tank
PLC
electromagnetic valve