发电机和磁装置是发电机组中密切相关的两个部分。任一部分出现故障,发电机将无法正常运行。通过对发电机无法起励的原因进行综合分析,提出了一些相应的排查故障的方法,使发电机能尽快投入正常使用。
Generator and excitation device are two inseparable parts of the generator unit.once whichever goes wrong,the generator unit can't operate normally. This article analyzes the reasons for generator unable to excitation and presents several methods for eliminating the failure,in order to operate the unit normally as soon as possible.
出处
《机电工程技术》
2013年第7期94-96,共3页
Mechanical & Electrical Engineering Technology
关键词
发电机
励磁装置
无法起励
转速太低
频率
generator
excitation device
unable to excitation
low revolving speed
frequency