摘要 中国溪洛渡贵广一回、贵广二回等直流输电工程中均采用了直接光触发晶闸管换流阀。为了满足超高压、特高压工程的要求,换流阀采用众多晶闸管的串联技术。为了确保触发的可靠性,作为后备紧急保护触发,在每个晶闸管内部有集成了转折二极管(BOD)电路。笔者就该电路的工作原理和单阀中允许最多BOD触发晶闸管级数的限定原则进行分析。 Light triggered thyristor valves have been widely used in many Chinese HVDC or UHVDC power transmission projects, such as Xiluodu Project, GG I Project, and GG II Project, where many thyristors are connected in series in a thyristor valve. Break over diode (BOD) circuits are integrated into each thyristor to ensure reliable stand-by emergent protective triggering. The author analyzes the working principle of BOD circuit, and discusses the limiting principle of the maximum number of thyristors triggered by the BOD circuits in a thyristor valve.
作者 张建峰
出处 《高压电器》 CAS CSCD 北大核心 2013年第8期112-114,共3页 High Voltage Apparatus
关键词 转折二极管 光分配器 换流阀 break over diode(BOD) multimode star coupler(MSC) thyristor valve
  • 相关文献

参考文献7

二级参考文献38

  • 1王明新,谢国平.高压直流输电开路试验原理的探讨[J].电网技术,2004,28(22):11-14. 被引量:31
  • 2李立浧.特高压直流输电的技术特点与工程应用[J].电力设备,2006,7(3):1-4. 被引量:67
  • 3崔东,冯建强,贾涛,王韵,王建生,郑军.±500kV HVDC换流阀冲击试验技术[J].电力设备,2006,7(3):30-32. 被引量:11
  • 4云南-广东±800kV特高压直流输电工程技术规范[Z].广州:南方电网技术研究中心.2007.
  • 5云广工程绝缘配合研究报告.ED3_061[1].CS-0[R].广州:南方电网研究中心.2007.
  • 6张文亮,于永清,李光范,范建斌,宿志一,陆家榆,李博.特高压直流技术研究[J].中国电机工程学报,2007,27(22):1-7. 被引量:365
  • 7GB/T20990.1-2007高压直流输电晶闸管阀第一部分:电气试验[S],2007.
  • 8IEC60700-1--2008. Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing[S].
  • 9GB/T20990.1-2007.高压直流输电晶闸管阀·第一部分:电气试验[S].
  • 10ZHOU Hui-gao. Simulation and comparison of the STC for thyristor valves for HVDC by software PSCAD [J]. The Journal of CPRI, 2006, 3(1):21-28.

共引文献205

同被引文献22

引证文献5

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部