期刊文献+

剪切型多自由度结构的层间初始侧移刚度实测方法 被引量:1

STIFFNESS MEASUREMENT METHOD OF SHEARING MDOF STRUCTURE
原文传递
导出
摘要 用拟动力试验方法研究剪切型多自由度结构的抗震性能,碰到的首要问题是如何测准剪切型多自由度结构的层间初始侧移刚度。该文的研究表明,由于多个作动器之间存在耦合现象,使得采用常规的多作动器测试方法很难测准剪切型多自由度结构的侧移刚度。采用作者改进的单作动器测试方法能够有效地解决多个作动器的耦合问题,准确测出多自由度结构的刚度。通过实例分析表明:采用新方法测试的试验刚度多次测量结果稳定,且与经典的理论分析结果一致,证明了作者推荐的单作动器刚度测试方法的有效性和准确性。 How to measure the initial elastic lateral stiffness accurately is the first problem of pseudo dynamic testing for researching seismic performance of shearing MDOF (Multiple Degree of Freedom Systems) structure. Multi-Servo-hydraulic control systems of shearing MDOF pseudo dynamic testing have the phenomena of coupling, leading to difficulties in obtaining true lateral stiffness. A new method of measuring story lateral stiffness (Simple-Servo-hydraulic measure method) is presented in this paper. An example is used to demonstrate that the result of the new method is steady. The analysis results showed the testing results are comparable with the calculate results. The analyses illustrates the accuracy of the proposed method.
出处 《工程力学》 EI CSCD 北大核心 2013年第8期90-95,共6页 Engineering Mechanics
基金 国家自然科学基金项目(51078132) 2009教育部创新团队项目(IRT0917)
关键词 侧移刚度 多作动器测试方法 单作动器测试方法 拟动力试验 剪切型多自由度结构 lateral stiffness multi-servo-hydraulic measurement method simple-servo-hydraulic measurementmethod pseudo dynamic testing shearing MDOF structure
  • 相关文献

参考文献11

  • 1Seible F, Hegemier G A, Igarashi A, Kingsley G R. Simulated seismic-load tests in full-scale five-story masonry building [J]. Journal of Structural Engineering, 1994, 120(3): 903--924.
  • 2Seible F, Priestley M J N, Kingsley G R, Kurkchubasche A G. Seismic response of full-scale five-story reinforced-masonry building [J]. Journal of Structural Engineering, 1994, 120(3): 925--947.
  • 3Priestley M J N. Seismic design of concrete masonry shearwalls [J]. ACI Journal, 1986, 83(1): 58--68.
  • 4陈思甜.用电液伺服系统测试两层刚架结构的侧移刚度[J].重庆交通学院学报,1991,10(1):39-43. 被引量:1
  • 5卢铁鹰,陈思甜.用MTS电液伺服结构试验系统进行结构拟动力试验的控制程序研究[J].工程力学,1990,7(3):127-131. 被引量:2
  • 6谭素杰.抗震结构合理刚度的研究[D].哈尔滨工业大学.1997:39-48.
  • 7GB50011-2001,建筑抗震设计规范[s].第1版.北京:中国建筑工业出版社,2002:1-191.
  • 8Drysdale R G, Khattab M M. In-plane behavior of grout concrete masonry under biaxial. Tension-Compression [J]. ACI Structural Journal, 1995, 92(6): 653--664.
  • 9GB50003-2001.砌体结构设计规范[s].北京:中国建筑工业出版社,2002.
  • 10孙国华,何若全,顾强,郁银泉,方有珍.半刚接钢框架内填RC墙结构侧移刚度分析[J].沈阳建筑大学学报(自然科学版),2011,27(4):613-620. 被引量:5