摘要 为了解决断续电流模式下的Buck直流变换器建模困难的问题,针对这个离散的、时变的、非线性系统,提出引入虚拟开关数将一个开关周期中的三种电路拓扑统一到一组状态空间方程中。在应用动态相量法时,为保证模型的合理性,动态相量模型中保留傅里叶级数中的直流量、基频分量和二次分量,讨论虚拟开关占空比的取值,建立其非线性、大信号、时不变模型。仿真结果表明,动态相量模型接近于时域模型,验证了动态相量模型的合理性。 In order to solve the problem of modeling on the Buck DC-DC converter working in discontinuous conduction mode(DCM),which is a discrete,time-varying,nonlinear system,three circuit topologies in a switching cycle are unified to a set of state space equations by a virtual function.When using the dynamic phasor,the DC component,fundament frequency component and second harmonic components of Fourier series are retained in order to ensure the rationality of the model.The value of the virtual switch duty cycle is discussed and a non-linear,large signal,time-invariant model is built.Simulation results show that the dynamic phasor model is similar to the time-domain model.Its validation is also proved.
出处 《西安邮电大学学报》 2013年第4期41-45,共5页 Journal of Xi’an University of Posts and Telecommunications
基金 国家青年自然科学基金资助项目(51205309) 西安邮电学院青年教师科研基金资助项目(ZL2011-10)
关键词 Buck直流变换器 断续电流模式 动态相量法 虚拟开关 direct current-direct current(Buck DC-DC) converter discontinuous conduction mode(DCM) dynamic phasors virtual switch
  • 相关文献

参考文献9

二级参考文献47

  • 1岳程燕,周孝信,李若梅.电力系统电磁暂态实时仿真中并行算法的研究[J].中国电机工程学报,2004,24(12):1-7. 被引量:68
  • 2岳程燕,田芳,周孝信,吴中习,李若梅.电力系统电磁暂态-机电暂态混合仿真接口实现[J].电网技术,2006,30(4):6-10. 被引量:51
  • 3周孝信 李汉香 等.电力系统分析[M].北京:电力出版社,1989..
  • 4夏道止.电力系统分析[M].西安:西安交通大学出版社,1994..
  • 5白济民.直流输电系统引起的次同步振荡[M].北京:清华大学,1989..
  • 6[1]Sanders S R, Noworolski J M, Liu X Z, et al. Generalized averaging method for power conversion circuits [J]. IEEE Trans on Power Electronics, 1991, 6(2):251-259.
  • 7[3]Stankovic A M, Mattavelli P, Caliskan V, et al. Modeling and analysis of FACTS devices with dynamic phasors[A]. IEEE Power Engineering Society Winter Meeting, 2000. , Singapore[C], Jan. 2000, 2:1440-1446.
  • 8[4]Stefannov P C, Stankovic A M, Modeling of UPFC operation under unbalanced conditions with dynamic phasors [J]. IEEE Trans on Power Systems, 2002, 17(2):395-403.
  • 9[5]Stankovic A M, Sanders S R, Dynamic phasors in modeling and analysis of unbalanced polyphase AC machines [J]. IEEE Trans on Energy Conversion, 2002, 17(1):107-113.
  • 10[6]Shengli Huang, Xiaoxin Zhou, Analysis of balanced and unbalanced faults in power systems using dynamic phasors [A]. ICEE-PES/CSEE, POWERCON2002, Kunming[C], China, 2002.

共引文献121

同被引文献14

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部