摘要 低应力破坏是焊接结构常见的断裂形式之一,为确定其影响因素,采用插销法焊接试验和扫描电镜断口观察,研究了低合金钢焊接热影响区的静载断裂特性。试验结果表明,为防止焊接热影响区产生低应力断裂,采用预热措施是十分有效的;预热80℃以上时,断裂强度与母材强度相接近。断口观察表明,不预热时绝大部分为结晶状断口,微观上呈现氢致沿晶断裂和氢致准解理断裂;预热时绝大部分是纤维状断口,微观上呈韧窝状。 Low stress failure was one of common fractures of welded structure. In order to determine the influen- cing factors, the static load fracture characteristics of heat affected zone in low alloy high strength steel were stud- ied by implant test and the SEM observation. The results show that preheating is valuable to prevent HAZ from low stress fracture. Preheating to 80 ℃ the fracture strength of HAZ is nearly equivalent to that of base metal. The SEM observation of the fracture surface reveals that the hydrogen-induced intergranular fracture and hydro- gen-induced quasi-cleavage fracture is an overwhelming majority in non-preheated HAZ. When HAZ is preheated, the fibrous facture is majority, in micro presentation, it shows the dimple-like fracture. Key words:low alloy steel;heat affected zone; static load ;fracture characteristics
出处 《钢铁研究学报》 CAS CSCD 北大核心 2013年第4期49-53,共5页 Journal of Iron and Steel Research
关键词 低合金钢 热影响区 静载 断裂特性 low alloy steel heat affected zone static load fracture characteristics
  • 相关文献

参考文献4

二级参考文献12

  • 1朴东光.焊接领域的标准化及合格评定——现状与未来[J].焊接,2006(6):27-34. 被引量:2
  • 2吕向阳,1988年
  • 3团体著者,第五届全国焊接学术会议论文集,1986年
  • 4刘永辉,1986年
  • 5程永兴,金属学报.A,1985年,21卷,1期,75页
  • 6Pellini W S..结构完整性原理[M].北京:国防工业出版社,1983.
  • 7佐藤邦彦.溶接工业[M].日本:理工学社,1979.
  • 8张玉凤.静载下焊缝强度匹配对结构抗断裂性能影响的研究.天津大学学报,1985,(3):13-18.
  • 9九田一久.先进钢技术に关する日米共同研究につぃて[J].防卫技术ヅャ-ナル.2000(8),5-11.
  • 10NDSZ 3001调质高张力钢用被覆ア-ク溶接棒[S].1975.

共引文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部