摘要 为了补偿电网中无功负荷特别是冲击性无功负荷增加的电损耗,保证良好的电能质量,简要分析某制酸企业生产中影响电能质量主要因素,提出采用静止无功补偿器(SVC)进行就地补偿,并进行实例分析。结果表明采用SVC可以有效补偿无功电损耗,稳定系统电压,且节能效果也很突出。 In order to compensate the reactive load in the power grid,particularly the electricity loss increased by impact reactive load,ensure good electrical energy quality,the main influencing factors for the electrical energy quality during production in a acid production enterprise are briefly analyzed,the use of static Var compensator(SVC) for local compensation is proposed,and the analysis of an actual case is conducted.The results indicate that by using the SVC,it can effectively compensate the reactive electricity loss,stabilize the voltage in the system,and also offers outstanding energy-saving effect.
出处 《硫磷设计与粉体工程》 2013年第4期45-48,52,共4页 Sulphur Phosphorus & Bulk Materials Handling Related Engineering
关键词 制酸企业 电能质量优化 无功补偿 acid production enterprise electrical energy quality optimization reactive compensation
  • 相关文献

参考文献4

  • 1王兆安,杨君,刘进军.谐波抑制和无功率补偿[M].北京机械工业出版社,2005:175-187.
  • 2莫正康.半导体变流技术[M].北京:机械工业出版社,2000..
  • 3蒋平,赵剑锋,唐国庆.串联型电能质量补偿器的实验研究[J].电力系统自动化,2001,25(4):41-44. 被引量:20
  • 4刘介才.工厂供配电[M].北京:机械工业出版社,2006:9-44.

二级参考文献6

  • 1Woodley N H,IEEE Trans Power Delivery,1999年,14卷,3期,1181页
  • 2Zhao Jianfeng,Proc IEEE PEDS'99,1999年
  • 3Hingorani N G,IEEE Spectrum,1995年,32卷,6期,41页
  • 4Van Der Broeck H W,IEEE Trans Industrial Applications,1988年,24卷,1期,142页
  • 5Campos A,IEEE Trans Industrial Electronics,1999年,39卷,2期,159页
  • 6李庚银,陈志业,丁巧林.用于有源补偿器的广义瞬时无功电流实时检测方法[J].电力系统自动化,1997,21(10):28-31. 被引量:29

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部