摘要
采用电子梁式倾斜仪对北京地铁13号线路基沉降进行监测,分析了监测结果的稳定性、温度特性和可靠性。结果表明,电子梁式倾斜仪的测试数据可靠,方法简便,在一定领域内可以代替静力水准测量法。
Electronic beam inclinometer is used then analyze stability, temperature characteristic data obtained by electronic beam inclinometer substitute for static leveling to a certain extent. to monitor subgrade settlement of Beijing Metro Line 13, and and reliability of the detecting data. The result shows that the is reliable, and the detection method is simple and may a
出处
《路基工程》
2013年第4期172-175,共4页
Subgrade Engineering
关键词
轨道交通
路基
滑塌
电子梁式倾斜仪
自动化监测
无线传输
track traffic
subgrade
collapse
electronic beam inclinometer
automatic monitoring
wireless transmission