期刊文献+

电网不平衡下基于自适应观测器的锁相环研究 被引量:18

Phase-locked loop algorithm based on adaptive observer under unbalanced grid voltage condition
下载PDF
导出
摘要 电网不平衡条件下,传统软件锁相环已经不能准确跟踪电网电压的频率和相位信息,且无法直接得到电网电压的正负序分量。针对传统软件锁相环的缺陷,提出了一种静止坐标系下基于自适应观测器的软件锁相环算法。算法设计了电网电压角频率的自适应观测器模型,通过定义Lyapunov函数,推导出电网角频率的自适应律,并设计了使得观测器稳定的增益矩阵。该算法不仅可以观测到电网的频率、相位等信息,同时可以得到电网电压正负序分量。仿真和实验结果表明,基于自适应观测器的锁相环具有检测精度高、动态效果好等优点,当电网处于各种不平衡条件时更能显示其优越性,可为风电网侧变流器的算法改进提供有效的控制基准。 Under the condition of unbalance grid voltage, traditional phase-locked loop (PLL) is incapable to track the frequency and phase of the voltage, and fails to get the positive and negative sequence components of the grid voltage directly. To solve this problem a PLL algorithm based on adaptive observer in the fixed reference coordinates is presented. The adaptive observer model and gain matrix for grid angular frequency estimation is designed. By means of Lyapunov function definition, the adaptive law for the grid angular frequency is deduced. The proposed PLL algorithm not only can observe the frequency and phase angle of the grid voltage, but also can get the positive and negative sequences signals. Simulation and experimental results prove that PLL based on the adaptive observer has advantage of high precision, fast dynamic response and so on. Its advantages are more prominent in the unbalance conditions, so it can provide a reliable control foundation for the improvement of wind energy converter.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2013年第15期120-125,共6页 Power System Protection and Control
基金 863计划课题(2011AA050204)~~
关键词 电压不平衡 自适应观测器 锁相环 正负序分量 风电变流器 unbalanced grid voltage adaptive observer phase-locked loop positive and negative sequences wind energy converter
  • 相关文献

参考文献10

  • 1徐海亮,章玮,胡家兵,贺益康,周鹏.电网电压不平衡及谐波畸变时基波电压同步信号的检测[J].电力系统自动化,2012,36(5):90-95. 被引量:51
  • 2Lee Kyoung-Jun, Lee Jong-Pil, Kim Tae-Jin, et al. A novel active power filter for selective harmonic suppression based on a robust PLL Algorithm[C]//2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems, Aalborg, June 25-28, 2012: 416-422.
  • 3张治俊,李辉,张煦,周小铃,王亚飞,李学伟.基于单/双同步坐标系的软件锁相环建模和仿真[J].电力系统保护与控制,2011,39(11):138-144. 被引量:61
  • 4Sharma D, Sen B, Babu B C. Improved grid synchronization algorithm for DG system using DSRF PLL under grid disturbances[C] // 2012 Students Conference on Engineering and Systems, Allahabad, Uttar Pradesh, 16-18 March, 2012: 1-6.
  • 5Carugati I, Maestri S, Donato P G, et al. Variable sampling period filter PLL for distorted three-phase systems[J]. IEEE Trans on Power Electronics, 2012, 27(1): 321-330.
  • 6侯世英,张诣.电压频率偏移条件下新型锁相环在三相电压型PWM整流器中的应用[J].电力系统保护与控制,2011,39(17):74-79. 被引量:6
  • 7Shin Woo-Yeol, Kim Manho, Hong Gi-Moon, et al. A fast-acquisition PLL using split half-duty sampled feedforward loop filter[J]. IEEE Trans on Consumer Electronics, 2010, 56(3): 1856-1859.
  • 8Sen B, Sharma D, Babu B C. DSRF and SOGI based PLL-two viable scheme for grid synchronization of DG systems during grid abnormalities[C] // 2012 Students Conference on Engineering and Systems, Allahabad, Uttar Pradesh, 16-18 March, 2012: 1-6.
  • 9Escobar G, Martinez-Montejano M F, Valdez A, et al. Fixed reference frame phase-locked loop for grid synchronization under unbalanced operation[J]. IEEE Trans on Industrial Electronics, 2011, 58(5): 1943-1951.
  • 10姚骏,陈西寅,廖勇,黄嵩.电网电压不平衡时永磁直驱风电机组的控制策略[J].电力系统保护与控制,2011,39(14):99-106. 被引量:18

二级参考文献48

  • 1王永,沈颂华,关淼.新颖的基于电压空间矢量三相双向整流器的研究[J].电工技术学报,2006,21(1):104-110. 被引量:20
  • 2徐健飞,庞浩,王赞基,陈建业.新型全数字锁相环的逻辑电路设计[J].电网技术,2006,30(13):81-84. 被引量:21
  • 3宋强,刘钟淇,张洪涛,刘文华.大功率电力电子装置实时仿真的研究进展[J].系统仿真学报,2006,18(12):3329-3333. 被引量:21
  • 4Zhan Changjiang, Fitzer C, Ramachandaramurthy V K, et al. SoRware phase-locked loop applied to dynamic voltage restorer (DVR) [C]. // Proc. IEEE Power Eng Soc Winter Meeting, 1033-1038.
  • 5Chung Se-kyo. A phase tracking system for three phase utility interface inverters[J]. IEEE Transactions on Power Electronics, 2000, 15 (3): 431-438.
  • 6Hilmy Awad, Jan Svensson, Bollen M J. Tuning software phase-locked loop for series-connected converters[J]. IEEE Transactions on Power Delivery, 2005, 20 ( 1 ): 300-308.
  • 7Karimi-Ghartemani M, Iravani M R. A method for synchronization of power electronic converters in polluted and variable-frequency environments[J]. IEEE Trans onPower Systems, 2004, 19: 1263-1270.
  • 8Ghosh A, Joshi A. A new algorithm for the generation of reference voltages of a DVR using the method of instantaneous symmetrical components[J]. IEEE Power EngRev, 2002, 22 (1): 63-65.
  • 9Rodriguez P, LunaA, Ciobotaru M, et al. Advanced gid synchronization system for power converters under unbalanced and distorted operating conditions[C].//Proc of the 32st Annual Conference of the IEEE Industrial Electronics Society, IECON, 2006: 5173-5178.
  • 10Pedro Rodriguze, Josep Pou Joan Bergas. Decoupled double synchronous reference frame PLL for power converters control[J]. IEEE Transactions on Power Electronics, 2000, 22 (2): 584-592.

共引文献128

同被引文献130

  • 1蒋卫宏.不对称电网故障下PWM整流器的控制策略研究[J].系统仿真学报,2007,19(15):3527-3530. 被引量:11
  • 2CARUGATI I,MAESTRI S,DONATO P G,et al.Variable sampling period filter PLL for distorted three-phase systems[J].IEEE Transactions on Power Electronics,2012,27(1):321-330.
  • 3SINGH B, SAHA R, CHANDRA A, et al. Static synchronous compensators (STATCOM): a review[J]. Power Electronics, IET, 2009, 2(4): 297-324.
  • 4GRINO R, CARDONER R, COSTA-CASTELLO R, et al. Digital repetitive control of a three-Phase four-wire shunt active filter[J]. IEEE Transactions on Industrial Electronics, 2007, 54(3): 1495-1503.
  • 5SOZANSKI K E Sliding DFT control algorithm for three-phase active power filter[C] // Applied Power Electronics Conference and Exposition, Twenty-First Annual IEEE. Dallas TX, USA: IEEE, 2006: 1223-1229.
  • 6SVENSSON J,BONGIORNO M, SANNINO A.Practical implementation of delayed cancellation methodfor phase sequence separationfJ]. IEEE Transactions onPower Delivery, 2007,22(1): 18-26.
  • 7BRENNA M, LZLAZAROIU Q SUPERTI-FURGA Q etal. Bidirectional front end converter for DG withdisturbance insensitivity an islanding detection capability [J].IEEE Transactions on Power Delivery, 2008, 23(2):907-914.
  • 8SACCOMANDO G, SVENSSON J. Transient operationof grid-connected voltage source converter underunbalanced voltage conditions[C] // Proc 3 6th IAS Annu.Meeting IEEE Ind, 2001,4: 2419-2424.
  • 9FREIJEDO F, DOVAL-GANDOY J, LOPEZ 0,et al. Ageneric open-loop algorithm for three-phase gridvoltage/current synchronization with particular referenceto phase, frequency and amplitude estimation[J]. IEEETransactions on Power Delivery, 2009, 24(1): 94-107.
  • 10TIMBUS A, TEODORESCU R, BLAABJERG F, et al.Synchronization methods for three phase distributedpower generation systems[C] // Proc IEEE 36th PowerElectron Specialists Conf (PESC), June, 2005: 2474-2481.

引证文献18

二级引证文献115

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部