期刊文献+

房间空气调节器用铜管的应力应变限值的推算 被引量:1

The calculation of limit numerical value of stress distortion on brass tube for room Air-conditioner use
下载PDF
导出
摘要 在房间空气调节器中,由于铜管与压缩机是刚性连接的,压缩机在工作中产生的振动会作用在铜管上而使铜管产生疲劳。因此,在实际应用中必须严格控制铜管的应力应变值,以防止铜管疲劳断裂。本文对空调器用铜管的应力应变限值进行了初步的推算与分析。 In the room air-conditioner, as the brass tube and the compressor are rigid connected, the quiver of the compressor while running can effect on the brass tube to make it wear down. So, in practice use, we must control the limit numerical value of stress distortion on brass tube strictly, so as to prevent the brass tube from wearing down. The calculation of limit numerical value of stress distortion on brass tube for room air-conditioner use is researched in this paper.
作者 谭成斌
出处 《家电科技》 2013年第7期60-61,共2页 Journal of Appliance Science & Technology
关键词 应力应变 铜管 空调器 推算 Stress distortion, Brass tube: Room air-conditioner, Calculation
  • 相关文献

参考文献2

  • 1张铁雁,姜俊明,陈建民等.中华人民共和国国家标准房间空气调节器.北京:中国标准出版社,2005.
  • 2邱宣怀等.机械设计.北京:高等教育出版社,4版.