液相沉积过程中反应液pH值对钛瓷结合强度的影响

Effect of liquid-phase deposition with different pH value on bonding strength of porcelain and pure titanium
下载PDF
导出
摘要 目的:研究以不同pH值反应液行纯钛表面液相沉积处理后对钛瓷结合强度的影响。方法:36个纯钛试件随机分为3个实验组和1个对照组(n=9),经喷砂处理后3个实验组分别置于pH值为8、9、10的反应液中进行液相沉积处理。然后分别用扫描电镜观测试件的表面形貌;接触角测量仪测量钛-蒸馏水表面接触角;最后参照IS09693(1999)Amd.1 2005(E)标准在各组试件的中部烧结瓷层用万能试验机测各组试件的钛瓷结合强度;扫描电镜观察钛瓷结合界面形貌。结果:各实验组钛瓷结合强度均明显高于对照组(P<0.05);pH 9组钛瓷结合强度分别高于pH 8组和pH 10组(P<0.05)。结论:用液相沉积法在纯钛表面制备中间层可明显提高钛瓷结合强度,当反应液pH值为9时钛瓷结合强度最高。 AIM: To investigate the effect of liquid-phase deposition(LPD) with different pH value on the bonding strength in the middle layer of titanium and porcelain . METHODS: 36 pure titanium specimens were sandblasted and treated by LPD at pH 8, pH 9, pH 10 and without LPD treatment (the controls) respectively(n = 9). The interface of titanium and porcelain was observed by scanning electron microscope (SEM). The contact angle of titanium surface with H20 was measured. A three-point-flexure-test was used to measure the bonding strength of titanium to porcelain. RESULTS: Better continuity and thickness uniformity of the interface of titanium and porcelain were observed in LPD at pH 9 treated samples. The contact angle values were in the order of pH 8 group 〉 control group 〉 pH 10 group 〉 pH 9 group. The bonding strength of the LPD treated samples was significantly higher than that of the controls (P 〈 0.05 ), that of LPD at pH 9 treated samples was the highest( P 〈 0.05 ). CONCLUSION: LPD at pH 8 10 may improve the bonding strength of porcelain and pure titanium in the middle layer . LPD at pH 9 may show highest effect.
机构地区 解放军第 解放军第
出处 《牙体牙髓牙周病学杂志》 CAS 北大核心 2013年第8期528-531,共4页 Chinese Journal of Conservative Dentistry
基金 南京军区医学科技创新课题面上项目(10MA048)
关键词 液相沉积 中间层 PH值 钛瓷结合强度 liquid-phase deposition middle layer pH titanium-porcelain bonding strength
  • 相关文献

参考文献14

  • 1Starosvetsky D, Gotman I. Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy [ J ]. Biomaterials, 2001 , 22(13) : 1853 - 1859.
  • 2International Organization for Standardization. ISO 9693 ( 1999 ) Amd. 1 2005 (E). Metal-ceramic dental restorative systems [ S]. ISO/TC, 2005.
  • 3任卫红,郭天文.钛的氧化行为对钛瓷结合力的影响[J].实用口腔医学杂志,2007,23(4):554-557. 被引量:11
  • 4Lee KM, Cai Z, Griggs JA, et al. SEM/EDS evaluation of porcelain adherence to gold-coated cast titanium [J]. J Biomed Mater Res, 2004, 68(2) : 165 - 173.
  • 5王舒舒,张蜡宝,光寒冰,周淑,章非敏.磁控溅射氮化铌对钛-瓷结合强度的影响[J].中华口腔医学杂志,2010,45(5):313-317. 被引量:3
  • 6姜涛,胡江,周健,唐长斌,高勃.纯钛表面电火花沉积中间层对钛瓷结合强度的影响[J].口腔医学研究,2011,27(4):277-280. 被引量:3
  • 7Hautaniemi JA, Hero H, Juhanoja JT. Porcelain bonding on Ti : its dependence on surface roughness, firing time and vacuum level[J]. Surf Intersurf Anal, 1993, 20(3): 421 - 426.
  • 8McLwan JW,Sced IR. Bond of dental porcelain to metal[J]. J BrCeram Soc, 1973, 5(2) :229 - 235.
  • 9Lavine MH, Custer R. Variables affecting the strength of bond be- tween porcelain and gold[J]. J Dent Res, 1966, 45(1) :32 - 35.
  • 10Kelly M, Asgar K, O Brien WJ. Tensile strength determination of the interface between porcelain fused to gold [ J ]. J Biomed MaterRes, 1969, 3(3):403 - 407.

二级参考文献95

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部