摘要 目的探讨改良抽出钢丝法治疗指伸肌腱止点损伤的方法,以减少并发症。方法2006年5月至2012年6月,采用改良抽出钢丝法治疗指伸肌腱止点损伤46例47指,克氏针纵形穿末节指骨而不穿过远指间关节,尾端折成“z”形弯钩;钢丝于伸肌腱止点以近0.8~1.0cm处如同Kessler缝合法穿过,两端经末节指骨基底两侧系于克氏针弯钩处拧紧。结果术后随访8~33个月,手指远指间关节活动度在50~一7俨,无并发症。按Dargan功能评定法评定:优42例43指,良4例4指;优良率为100%。结论改良抽出钢丝法治疗伸肌腱止点损伤,方法简单、廉价而并发症少,治疗效果满意。 Objective To explore the modified pullout wire technique for treatment extensor tendon insertion injuries and discuss ways to decrease complications. Methods From May 2006 to June 2012, 46 eases 47 fingers of extensor tendon insertion injuries were treated with modified pullout wire technique. A Kirschner wire (K-wire) was longitudinally inserted into the distal phalanx without going through the DIP joint. The end of the K-wire was bent to form a "Z" shaped hook. A stainless steel wire was threaded through the extensor tendon about 8 to 10 mm to the insertion in a Kessler suture fashion and then went through the phalanx base on both sides to be fastened on the K-wire hook. Results All eases were follow-up for 8 to 33 months postoperatively. DIP joint range of motion was between 50° and 70°. No complications were observed. According to Dargan scales, the result was excellent in 42 eases 43 lingers and good in 4 eases 4 fingers, with the exeellent and good rate being 100%. Conclusion The modified pullout wire technique leads to satisfactory results and should be a predictable, low-morbidity, low-cost treatment, safe and simple method for treatment of extensor tendon insertion injuries.
出处 《中华手外科杂志》 CSCD 北大核心 2013年第4期237-238,共2页 Chinese Journal of Hand Surgery
关键词 指损伤 抽出钢丝法 Tendons Finger injuries Pullout button
  • 相关文献

参考文献8

二级参考文献15

  • 1陈履平,张诗兴,孙贤敏,李承球.陈旧性锤状指的显微解剖与治疗研究[J].中华手外科杂志,1994,10(1):34-36. 被引量:80
  • 2王欣,陈宏,王晓峰,章伟文.应用微型骨锚重建指伸肌腱终腱止点——附6例报告[J].中华手外科杂志,2005,21(6):360-361. 被引量:46
  • 3胡溱,王澍寰,黄啸元,胡琪.伸肌装置解剖及滑动的初步研究[J].中华手外科杂志,1996,12(A00):56-59. 被引量:8
  • 4李炳万 刘云江.实用手外科学上册[M].长春:吉林人民出版社,1990.12-15.
  • 5佐腾孝三 津下健哉.伸指结构的辅助组织[J].临床整形外科,1981,8(1):30-34.
  • 6Bonin N,Obert L,Jeunet L,et al.Reinsertion of the fleor tendon using a suture anchor:prospective study using early active motion.Chir Main,2003,22:305-311.
  • 7顾玉东 王澍寰 侍德.手外科学·第1版[M].上海科学技术出版社,2002.103.
  • 8Muzaffar AR,Orenstein HH.Use of the Mitek Mini G2 anchor for crossed intrinsic transfer.Plast Reconstr Surg,2000,105:467-470.
  • 9Brustein M,Pellegrini J,Choueka J,et al.Bone suture anchors versus the pullout hutton for repair of distal profundus tendon injuries:a comparison of strength in human ondaveric hands.J Hand Surg(Am),2001,26:489-496.
  • 10Abboud JA,Bozentka DJ,Soslowsky IJ,et al.Effect of Implant design on the cyclic loading properties of mini suture anchors in carpal bones.J Hand Surg(Am),2002,27:43-48.

共引文献128

同被引文献64

引证文献9

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部