目的:研究盐酸米诺环素滴耳液的制备方法。方法:采用UV法测定盐酸米诺环素含量,检测波长为347nm;并对36例化脓性中耳炎患者进行临床观察。结果:测得盐酸卡诺环素的x±s为(100.6±0.73)%。临床有效率为97.2%。结论:本制剂疗效可靠,分析方法快速简便。
Objective: To study the preparation of minocycline hydrochloride ear-drops. Method: The UV-speetropho
tometry was used for quantinative analysis. Detection wave-length was an 347nm. The clinieal therapentie effect was observed in 35
patients with otitis media snppurative. Results: The average recovery rates of minocycline hydrochloride was 100.6% RSD o.
73%). The elinieal effective rates was 97.2%. Conclusion: The preparation was effective and the method of determination is
smpla.
出处
《中国药师》
CAS
2000年第5期284-285,共2页
China Pharmacist
关键词
盐酸米诺环素
滴耳液
质量控制
化脓性中耳炎
Minocycline hydrochloride
Ear-drops
Quality control