期刊文献+

自适应小波尺度谱阈值在膈肌信号降噪的应用 被引量:1

Application of adaptive wavelet scalogram threshold in diaphragmatic electromyographic signal denoising
下载PDF
导出
摘要 膈肌肌电信号是人体微弱的生物电信号,此信号常受到心电信号的严重干扰。为了提高阈值在膈肌肌电信号降噪的准确度,提出了一种小波尺度谱阈值自适应的降噪算法。该算法先对膈肌肌电信号进行小波变换,再把小波系数转化为小波尺度谱,然后确定心电干扰位置,并且根据心电邻域小波能量自动调整阈值从而去除心电干扰。通过对膈肌肌电信号进行实验分析,并且与小波阈值方法进行对比,结果表明该方法降低了心电干扰并且保留了膈肌肌电信号的特征。 As weak bioelectricity signals, diaphragmatic electromyographic (EMGdi) signals are always corrupted by strong electrocardiography (ECG) signals. A denoising algorithm based on wavelet scalogram adaptive threshold was proposed in this paper to improve the precision of threshold in EMGdi signal denoising. This algorithm found the position of ECG interference by performing wavelet transform on the EMGdi signals and conveying wavelet coefficients to wavelet scalogram, and then automatically adjusted the threshold by ECG neighborhood wavelet energy in order to remove ECG interference. By comparing the results with the wavelet threshold, it shows that the proposed method can eliminate the ECG interference from EMGdi and reserve EMGdi signal characteristics effectively.
出处 《计算机应用》 CSCD 北大核心 2013年第9期2679-2682,共4页 journal of Computer Applications
基金 国家自然科学基金资助项目(60704045)
关键词 小波尺度谱 阈值自适应 心电干扰 膈肌肌电信号 wavelet scalogram adaptive threshold electrocardiography (ECG) interference diaphragmatic electromyographic (EMGdi) signal
  • 相关文献

参考文献12

  • 1STEIER J, JOLLEY C J, SEYMOURA J, et al. Increased load on the respiratory muscles in obstructive sleep apnea[ J]. Respiratory Physiology Neurobiology, 2010, 171 (1) : 54 - 60.
  • 2DENG C, WOLF W, BULLEMER F. Time frequency analysis of di- aphragmatic eleetromyogram for the detection of diaphragm fatigue [ C] // Proceedings of the 20th Annual International Conference of the IEEE EMBS. Piseataway, NJ: IEEE Press, 1988:3207-3210.
  • 3SLIM Y, RAOOF K. Removal of ECG interference from surface re- spiratory electromyography[ J]. IRMB, 2010, 31(4) : 209 - 220.
  • 4AITHOCINE E, GUMIRY P Y, MEIGNEN S, et al. Contribution to structural intensity tool: application to the cancellation of ECG in- terference in diaphragmatic EMG [ C]// Proceedings of the 28th IEEE EMBS Annual International Conference. Piscataway, N J: IEEE Press, 2006:5 - 8.
  • 5WITTEK A, ONO K, KAZJER J, et al. Analysis and comparison of reflex times and eleetromyograms of cervical muscles under impact loading using surface and fine-wire electrodes[ J]. IEEE Transac- tions on Biomedical Engineering, 2001,48(2) : 143 - 153.
  • 6谢燕江,杨智,范正平,罗远明.应用小波变换去除膈肌肌电图信号中的心电干扰[J].电子学报,2010,38(2):366-370. 被引量:11
  • 7季虎,孙即祥,林成龙.基于离散平稳小波变换的心电信号去噪方法[J].计算机应用,2005,25(6):1318-1320. 被引量:10
  • 8余丙星,蔡坤宝.小波尺度谱在吸毒者脉象信号检测中的应用[J].上海交通大学学报,2008,42(2):341-344. 被引量:3
  • 9LI C W, ZHENG C X, TAI C F. Detection of ECG characteristic points using wavelet transforms[ J]. IEEE Transactions on Biomedic- al Engineering, 1995, 42(1) : 21 -28.
  • 10ZHANG X Q, FANG J B, LIN C S, et al. Complexity analysis of dichotomy method in solving the approximated solution of equations [ C]//Proceedings of the 2011 IEEE International Symposium on IT in Medicine and Education. Piscataway, NJ: IEEE Press, 2011: 257 - 259.

二级参考文献21

  • 1何伟,陈良迟,徐晓红,谢正祥.心电信号及各组分的频率分布和有效带宽研究[J].生物医学工程学杂志,1996,13(4):336-340. 被引量:24
  • 2Luo Y M, Polkey M I, Johnson L C, et al. Diaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation[ J]. Journal of Applied Physiology, 1998, 85 (6) : 2089 - 2099.
  • 3Ungureanu M, Kroworsch B, Wolf W. Diaphragmatic EMG monitoring: Some aspects on specific signal processing requirements[ J] .Recent Res Devel Biomed Eng, 2002, 1 ( 1 ) :49 -66.
  • 4Marque C,Bisch C,Dantas R,et al. Adaptive filtering for ECG rejection from surface EMG recordings[J]. Journal Electmmyography and Kinesiology, 2005,15 ( 3 ) : 310 - 315.
  • 5Deng Y C,Woff W, Schnel R,et al. New aspects to event-synchronous cancellation of ECG interference: an application of the method in diaphragmatic EMG signals[ J]. IEEE Transactions on Biomedical Engineering,2000,47(9) : 1177 - 1184.
  • 6Elise A,Pierre-Yves G, Sylvain M, et al. Contribution to structural intensity tool: application to the cancellation of ECG interference in diaphragmatic EMG [ A ]. Proceeding of the 28th IEEE EMBS Annual International Conference[ C]. New York, USA: EMBS,2006.5 - 8.
  • 7Liang H L, Lin Z Y, Yin F L. Removal of ECG contamination from diaphragmatic EMG by nonlinear filtering [ J ]. Nonlinear Analysis, 2005.745 - 753.
  • 8Mak J N F, Hu Y, Luk K D K. ICA-based ECG removal from surface electromyography and its effect on low back pain assessment[ A ]. Proceeding of the 3rd International IEEE EMBS Conference on Neural Engineering[ C ]. Hawaii, USA: EMBS, 2007.646 - 649.
  • 9Roy S H, Bonato P, Knaflitz M. EMG assessment of back muscle function during cyclical lifting [ J ]. Journal Electromyography and Kinesiology, 1998,8(4) :233 - 245.
  • 10李仲宁,罗志增.基于小波变换的空域相关法在肌电信号中的应用[J].电子学报,2007,35(7):1414-1418. 被引量:31

共引文献21

同被引文献2

引证文献1

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部