期刊文献+

桩核印模完整性的临床调查 被引量:3

Investigating the integrity of impressions of a prepared dowel space
下载PDF
导出
摘要 目的:观察现阶段临床桩核印模的完整性,明确桩核印模出现缺损性缺陷的主要部位。方法:建立评价桩核印模完整性方法,将桩核印模分为桩核区、非桩核区、印模与托盘连接区,桩核区进一步细分为桩的根尖部、桩体部、牙本质肩领部、龈沟部。对156例临床桩核印模各区的完整性进行观察。结果:印模桩核区、非桩核区和连接区印模缺陷发生率依次为61.54%、45.79%、1.96%,桩核区印模缺陷的发生率显著高于其他区域(P<0.01);桩核区的根尖部、桩体部、牙本质肩领部、龈沟部印模缺陷发生率依次为36.54%、19.23%、0.64%、33.97%,桩核区印模的根尖部、龈沟部缺陷发生率显著高于桩体部和牙本质肩领部(P<0.01)。结论:本组临床桩核印模存在较高比例的缺陷;气泡性缺损好发于桩核区印模的根尖部;龈沟部印模不清晰。 Objective: To investigate the integrity of impressions of a prepared dowel space and to identify the main parts of defect of impressions.Method: A method for evaluating the integrity of impressions of a prepared dowel space was introduced.The impression of a prepared dowel space was divided into post and core area,non-post and core area,and impression and impression-tray joining area.And post and core area was furtherly divided into apical part,body part,dentin collar part,and gingival sulcus part.The method had been utilized for clinically evaluating 156 impressions of prepared dowel spaces to assign relevant values for each area of the impressions.Results: The results illustrated that the frequencies of occurrence of defects of the prepared dowel spaces were 61.54%,45.79%,and 1.96% in the post and core area,the non-Post and core area,and the impression and impression-tray joining area,respectively.;Occurrence frequency of defects in post and core area of the prepared dowel spaces was significantly higher than that of other areas of the prepared dowel spaces(P 0.01).Occurrence frequencies of defects of the prepared dowel spaces were 36.54% 、 19.23%,0.64%,and 33.97% in apical part,body part,dentin collar part,and gingival sulcus part of post and core area,respectively.Occurrence frequency of defects of apical part and gingival sulcus part was significantly higher than that of the body part and dentin collar part of Post and core area.Conclusions: High percentage of defects was found in clinical impressions of the prepared dowel space.Apical bubble defect occured frequently in apical part of post and core area.The impression in the gingival sulcus part of post and core Area was not clear.
出处 《口腔颌面修复学杂志》 2013年第1期26-29,共4页 Chinese Journal of Prosthodontics
关键词 桩核 印模 完整性 调查 post and core impression integrality investigation
  • 相关文献

参考文献5

二级参考文献16

  • 1徐君伍.口腔修复学,第4版[M].北京:人民卫生出版社,2000.27-88.
  • 2Craig RG. Review of dental impression materials[J]. Adv Dent Res, 1988, 2(1):51-64.
  • 3Skinner EW. A study of the accuracy of hydrocolloid impressions[J]. J Prosthet Dent, 1956, 6(1):80-86.
  • 4Appleby DC. The effect of powder/water ratio of irreversible hydrocolloid on the bond strength of irreversible hydrocolloid and agar combinations[J]. J Prosthet Dent, 1990, 64(4):508-509.
  • 5Morgano SM, Milot P. Clinical success of cast metal posts and cores[J]. J Prosthet Dent, 1993, 70(1):11-16.
  • 6ScottGK, HawkinsL, ChetwynJ, et al. Check bite impressions using irreversible alginate/reversible hydrocolloid combination.[J]. J Prosthet Dent, 1997,77 (1): 83-85
  • 7Heisler WH,Tian AH. Accuracy and bond strength of reversible with irreversible hydrocolloid impression systems:a comparative study[J]. J Prosthet Dent. 1992,68 (4):578-584
  • 8Herring HW, Tames MA,Zardiacks LD.Comparsion of the dimensional accuracy of a combined reversible lirreversible hydrocolloid impression system with other commonly used impression materials[J].J Prosthet Dent, 1984,52 (6): 795-799
  • 9Chee W W,Cho G C,Marzola R.An in vitro comparison of 5 techniques for impressing dowel space preparations.J Prosthodont,2000,9(1):19
  • 10Gilmore H W,Lund M R,Bales D J,et al.Operative Dentistry.4th ed.St Louis:C.V.Mosby Co,1982.358

共引文献47

同被引文献22

  • 1赵海军,刘国勤,季秋杰,张新海,刘海英.负压抽吸硅橡胶印模应用于铸造桩核冠修复的临床研究[J].海军医学杂志,2005,26(3):195-197. 被引量:5
  • 2林德胜,杨宏勇,王明辉.重建龈下缺损患牙生物学宽度的桩核冠修复[J].临床口腔医学杂志,2005,21(10):617-619. 被引量:3
  • 3陈治清.口腔材料学3版.北京:人民卫生出版社,2003:13-22.
  • 4Skinner EW. A study of the accuracy of hydrocoUoid iln- pres-sions[J]. J ProsthetDent, 1956, 6(1): 80-86.
  • 5Chee W W, Cho G C, Marzola R. An in vitro comparison of 5 techniques for impressing dowel space preparations [J]. J Prosthodont, 2000(1): 19.
  • 6GD mattison. Effect of post preparation on the apical seal[J]. J Prosthet Dent, 1984, 51:785.
  • 7Craig RG. Review of dental impression materials [J]. Adv DentRes, 1988, 2(1): 51-64.
  • 8Skinner EW. A study of the accuracy of hydrocolloid impres- sions[J]. JProsthetDent, 1956, 6(1): 80-86.
  • 9Appleby DC. The effect of powder/water ratio of irre- versible hy-drocolloid on the bond strength of irreversible hydrocolloid and agar combinations [J]. J Prosthet Dent, 1990, 64(4): 508-509.
  • 10陈怡清.口腔材料学|;M].4版.北京:人民卫生出版社,2008:42-43.

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部