期刊文献+

视网膜电图检测对视网膜静脉阻塞视功能的评价

The evaluate visual function of electroretinogram data on retinal vein occlusion
下载PDF
导出
摘要 目的探讨视网膜电图(electroretinogram,ERG)的检测对视网膜静脉阻塞(retinal vein occlusion,RVO)视功能评价的可能性。方法对21例RVO患者及23例正常对照组分别进行ERG检测,测a、b波振幅、峰港时和振荡电位振幅。结果 RVO组最大反应 a、 b波振幅较对照组明显下降.峰潜时延长,振荡电位幅值也明显降低,CRVO与BRVO组间有显著差异,说明随病变程度而加重。结论ERG检测可作为判断RVO视功能状态.病变程度及预后的客观重要手段。 Objective To probe the possibility visual function of electroretinogram (ERG)maximum combined response for retinal vein occlusion(RVO). Methods The ERG data were used in twenty--one patients with RVO and twenty--three control eyes, a. b -wave amplitude and impact time oscillatory potential (OPs )amplitude. Results The ERG a. b wave and OPs amplitude were signifilantly lower in RVO group than control group. a. b-wave impact time extend. It was positively correlated with severity of RVO. Conclusion It was important method that ERG data was used to judge visual function and degree outcome of RVO.
出处 《临床眼科杂志》 2000年第1期13-14,共2页 Journal of Clinical Ophthalmology
关键词 视网膜电图 振荡电位 视网膜静脉阻塞 Electroretinography Oscillatory Retinal vein occlusion