摘要
就热值变化对循环流化床锅炉经济性的影响进行了对比分析,主要从燃煤采购成本,运输成本,厂用电率及机组的损耗率等几个方面进行了分析,分析表明,在2500~3000 kcal/kg范围内,热值降低会导致电厂经济性降低。
The economical comparison between different heating value fuels in CFB boiler are discussed, especially purchase cost, transporting cost, house load and maintenance cost, according to the analysis it is known that the economy will decrease with the reducing of fuel heating value in the range of 2500-3000kcal/kg.
出处
《电站系统工程》
北大核心
2013年第4期80-81,共2页
Power System Engineering
关键词
循环流化床
低热值燃煤
经济性
circulation fluidization bed
low heating value fuel
economy