期刊文献+

Spontaneous urinary voiding of metallic screws in a patient with symphyseal plating for type II pelvic ring disruption

Spontaneous urinary voiding of metallic screws in a patient with symphyseal plating for type II pelvic ring disruption
原文传递
导出
摘要 With rapid advancement in surgical techniques and improvement in implant materials, rate of internal fixation for pubic symphyseal disruption in rotationally and vertically unstable pelvic ring injuries has increased. Among various modes of implant failure, screw/ plate breakage and loosening are common complications following unstable fixation. Migration of loose screws into the urinary bladder has been reported as an extremely uncommon complication of pubic symphyseal plating. Here we present a case report of a 52-year-old female who pre- sented with asymptomatic passage of screws in her urine following migration into the bladder, 2 years after symphy- seal plating for pubic diastasis in an anteroposterior compression pelvic ring injury.
出处 《Chinese Journal of Traumatology》 CAS CSCD 2013年第4期230-232,共3页 中华创伤杂志(英文版)
关键词 Pubic symphysis diastasis Bone plates Bone screws 螺丝松动 电镀金属 耻骨 骨盆 排尿 中断 植入材料 不稳定型
  • 相关文献

参考文献14

  • 1Blackmore CC, Cummings P, Jurkovich GJ, et al. Predict- ing major hemorrhage in patients with pelvic fracture. J Trauma 2006;61(2):346-52. 2.
  • 2Bagchi K, Uhl RL. Fixation of pubic symphyseal disruptions: one or two plates? Orthopedics 2009;32(6):427. 3.
  • 3Varga E, Hearn T, Powell J, et al. Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring. Injury 1995;26(2):75-80. 4.
  • 4Sagi HC, Papp S. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating. J Orthop Trauma 2008;22(6):373-8. 5.
  • 5Burgess AR, Tile M. Fractures of the pelvis. In: Rockwood CA, Green DP, Bucholz RW, eds. Fractures in adults. 3rd ed. Philadelphia: JB Lippincott, 1991:1399-442. 6.
  • 6Lindahl J, Hirvensalo E. Outcome of operatively treated type-C injuries of the pelvic ring. Acta Orthop 2005;76(5):667- 78. 7.
  • 7Putnis SE, Pearce R, Wali U J, et al. Open reduction andinternal fixation of a traumatic diastasis of the pubic symphysis. J Bone Joint Surg Br 2011;93(1):78-84. 8.
  • 8Morris SAC, Loveridge J, Smart DKA, et al. Is fixation failure after plate fixation of the symphysis pubis clinically important? Clin Orthop Relat Res 2012;470(8):2154-60. 9.
  • 9Heetveld M J, Poolman RW, Heldeweg EA, et al. Spontane- ous expulsion of a screw during urination: an unusual complica- tion 9 years after internal fixation of pubic symphysis diastasis. Urology 2003;61 (3):645. 10.
  • 10Fridman M, Glass AM, Noronha JA, et al. Spontaneous urinary voiding of a metallic implant after operative fixation of the pubic symphysis: a case report. J Bone Joint Surg Am 2003;85A (6):1129-32. 11.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部