摘要 通过开展液晶热像校准实验研究,分析了各测量参数对液晶热像测量精度的影响,得到了提高测量精度的有效方法,并对液晶热像技术应用于湍流传热研究进行了分析和讨论.实验结果表明,采用液晶图像滤波技术、控制液晶涂层厚度(>20μm)、减小光源照射角度以及提高液晶涂层的喷涂质量都有利于提高液晶热像的测量精度.最后,介绍了稳态和瞬态液晶热像技术在航空发动机透平叶片湍流对流冷却中的应用. By conducting a calibration experiment, the parameters affecting the measurement accuracy of the liquid crystal thermography has been analyzed, and the methods for improving the measurement accu- racy have been developed. Additionally, the application of the liquid crystal thermography technique in the study of turbulent flow heat transfer has been discussed. The experimental results showed that using the color imaging processing techniques, properly controlling the coating thickness (over 20 /~m), keeping the lighting angle as small as possible, and using a finely prepared thermochromatic liquid crystal (TLC) coat- ing can distinctively improve the measurement accuracy of the liquid crystal thermography. Finally, the applications of the steady and transient liquid crystal thermography technique in the study of the turbulent flow heat transfer have been described, which is related to the convective cooling of the aero-engine turbine blade.
作者 许亚敏 饶宇
出处 《上海交通大学学报》 EI CAS CSCD 北大核心 2013年第8期1185-1190,1197,共7页 Journal of Shanghai Jiaotong University
基金 国家自然科学基金资助项目(51176111 50806045)
关键词 液晶热像 传热测量 冷却技术 湍流 ., liquid crystal thermography heat transfer measurements cooling technology turbulent flow
  • 相关文献

参考文献14

  • 1Hallcrest Inc. Handbook of thermochromic liquid crystal technology [M]. Glenview, Illinois.. Hall crest Inc Press, 1991.
  • 2Rao Y, Zang S S. Calibrations and the measurement uncertainty of wide-band liquid cryslal thermography[J]. MeasSciTeehn, 2010, 21(1): 15105- 15112.
  • 3Ireland P T. Neely A J, Gillespie D, et al. Turhu- lent heat transfer measurements using liquid crystal [J]. IntJ Heat Fluid Flow, 1999, 20(4): 355 -367.
  • 4Ireland P T, Jones T V. Liquid crystal measure ments of heat transfer and surface shear stress[J] . Meas Sci Technol 2000, 11(7): 969-986.
  • 5Sabatino D R. Praisner T J, Smith C R. A high-ac- curacy calibration technique for thermochromic liquid crystal temperature measurement[J]. Exp Fluids, 2000, 28(6): 497-505.
  • 6Abdullah N, TalibARA, Saiah H RM. ezal. Film thickness effects on calibrations of a narrowband ther mochromic liquid crystal [J]. Exp Therm Fluid Sei. 2009, 33(4): 561 -578.
  • 7Behle M, Schulz K, l.einer W, et al. Color-based image processing to measure local temperature distri butions by wide-band liquid crystal thermography [J]. AppISci Res, 1996, 56(2-3): 13-43.
  • 8Maurcr M. Wolfersdorf J, Grilsch M. An experi mental and numerical study of heat transfer and pres- sure loss in a rectangular channel with V shaped ribs [J]. ASMEJ'rurbom, 2007, 129(4): 800-808.
  • 9Rao Yn. WanChaoyi. Xu Yamin, et al. Spatially-re- solved heat transfer characteristics in channels with pin fin and pin fin-dimple arrays [J]. Int J Thermal Sci. 2011, 50(11): 2277-2289.
  • 10Jenkins S C, Shevchuk I V, yon Wolfcrsdorf J, et al. Transient thermal field measurements in a high aspect ratio channel relaled to transient thermochro- mic liquid cryslal experiments [J]. ASME J Turbom, 2012. 134(3): No. 031002.