期刊文献+

一种基于金磁微粒的电化学发光免疫检测方法 被引量:5

An Electrochemiluminescence Immunoassay Based on GoldMag Particles
下载PDF
导出
摘要 基于金磁微粒(GoldMag particles)的磁性分离富集性能与良好的生物相容性,直接在金磁微粒表面吸附固定相思子毒素多抗制备捕获探针,以三联吡啶钌标记相思子毒素单抗作为电化学发光探针,两者与相思子毒素发生特异性免疫反应形成夹心复合物,成功建立了一种简单、快速、灵敏的相思子毒素电化学发光免疫检测方法。利用此方法检测相思子毒素,其浓度在0.2~1 500μg/L范围内与电化学发光强度成良好的对数线性关系,检出限为0.2μg/L。与生物素-亲和素固定法相比,该法的检出限相当,其线性范围更宽、操作更简化,具有通用性,可以此为基础发展生物毒素及其它蛋白的检测方法,用于临床诊断、环境监测及生物防护等领域。 A new efficient electrochemiluminescence(ECL) immunoassay strategy was developed for the determination of abrin based on the large specific surface area and excellent biocompatibility of GoldMag particles. The assay consisted of a double antibody sandwich format in which polyclonal an tibody (PeAb) of abrin was immobilized on GoldMag particles as capture probe, and Ru (bpy) ] 32+ -la- beled monoelonal antiboday (MeAb) for ECL probe. First, immobilized PcAb, abrin and Ru (bpy)32+-labeled McAb formed sandwich immunoeomplex via the specific immune response. Then abrin was determined by eleetrochemiluminescenee(ECL) reaction. A logarithmic linear relationship ( r = 0. 998 4) between ECL intensity and concentration of abrin in the range of 0. 2 - 1 500 μg/L was obtained, and the detection limit was 0.2 μg/L. Compared with the biotin - avidin immobilization method, this new approach possesses more considerable sensitivity, wider linear range, more simpli- fied steps and holds a great promise in the sensitive detection of target proteins in various fields such as clinical diagnosis, environmental monitoring and biodefense
机构地区 防化研究院
出处 《分析测试学报》 CAS CSCD 北大核心 2013年第8期998-1002,共5页 Journal of Instrumental Analysis
基金 总装预先研究资助项目(404070205)
关键词 金磁微粒 电化学发光 免疫检测 相思子毒素 GoldMag particles electrochemiluminescence immunoassay detection abrin
  • 相关文献

参考文献4

二级参考文献60

共引文献56

同被引文献20

引证文献5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部