摘要
阐述尿素装置各种液位计的优缺点及液位计测量不准的危害,分析液位计测量不准的原因,提出改进措施和避免类似问题发生的几点体会。
The advantages and disadvantages of various level meters used in urea plant were reviewed.The reason and the hazard of mismeasurement were presented together with the improvement measures to avoid similar problems occurring again.
出处
《大氮肥》
CAS
2013年第4期252-253,263,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
尿素装置
液位计
故障处理
urea plant
level meter
fault handling