期刊文献+

VolumeRAD成像技术与CT的图像质量及辐射剂量对比分析研究 被引量:2

Comparative Analysis of Imaging Quality and Radiation Doses Between Volume RAD and CT
原文传递
导出
摘要 目的分析比较VolumeRAD成像技术与CT的图像质量及辐射剂量,选择合适的X射线检查方式,更好地为临床应用。方法利用体模获取VolumeRAD成像技术、CT的图像并记录各自的辐射剂量。结果 Vol-umeRAD成像技术的低对比分辨力在对比度1%时为4 mm,对比度0.5%时为7 mm,对比度0.3%时为0 mm;高对比分辨力为9 lp/cm;辐射剂量1.26 mGy。CT的低对比分辨力在对比度1%时为2 mm,对比度0.5%时为4 mm,对比度0.3%时为6 mm;高对比分辨力7 lp/cm;辐射剂量28 mGy。结论 VolumeRAD成像技术的图像克服了DR的组织结构重叠,与CT相比,其高对比分辨力高,低对比分辨力低,但其辐射剂量远低于CT,且具有经济、简便、诊断价值强的特点。 Objective To study comparatively the imaging quality and radiation doses between VolumeRAD and CT in order to chose appropriate X - ray examination method for clinic. Methods To get VolumeRAD and CT images by the mod- ule and recorded each radiation doses. Results Low contrast resolutions were 4 mm ,7 mm and 0 mm when contrast were 1%, 0.5% and 0.3% respectively, and high contrast resolution was 9 lp/cm and radiation dose was 1.26 mGy in Vol- umeRAD, while in CT, low contrast resolutions were 2 mm,4 mm and 6 mm when contrast were 1% ,0.5% and 0.3% re-spectively and high contrast resolution was 7 lp/cm and radiation dose was 28 mGy. Conclusion VolumeRAD overcomes the overlaying structures of body tissues in DR and possesses higher high contrast resolution and lower low contrast resolution and much lower radiation dose compared with CT, which has economic, simple and high diagnostic value features.
出处 《中国辐射卫生》 2013年第4期388-390,395,共4页 Chinese Journal of Radiological Health
基金 山东省医药卫生科技发展计划项目(2011HW062) 山东省医药卫生青年项目(2011QW020)
关键词 VolumeRAD成像技术 DR CT 图像质量 辐射剂量 VolumeRAD DR CT Imaging Quality Radiation Dose
  • 相关文献

参考文献11

  • 1Yah H, Godfrey DJ, Yin FF. Fastreconststrution of digital to- mosynthesis using on boardimages [ J]. Med Phys, 2008,35 (5) :2 161 -2 169.
  • 2王巍,刘传亚,卢传友,秦维昌.数字合成X线体层成像原理与研究进展[J].医学影像学杂志,2005,15(7):606-609. 被引量:29
  • 3James T. l)oblfins III, H. Page MeAdams Chest tomosynthe- sis: Technical prin,'iples and clinical update[ J ] . European Journal of Radiology ,2009, ( 72 ) : 244 - 246.
  • 4Paseoal A, Lawinski CP, Mackenzie A, et al . a comparison of image quality and effective dose using ['our digital systems. Radiation Protection Dosimetry [ J ] Chest radiography 2005, 114:273-277.
  • 5赵丽琴,王克杨,贺文,胡志海,李辉,陈疆红,李娟,崔宝军,李志欣.数字化断层融合技术对肺结节筛查应用的初步研究[J].放射学实践,2010,25(11):1283-1286. 被引量:19
  • 6Dr. Si'an Phillips. Why Volume RAD[J] . GE Heahhcare, 2010,9:22 - 24.
  • 7MacMahon. H, Li F, Engelmann R, et al. Dual energy sub- traction and temporal subtraction chest radiography [ J ]. Jour- nal of Thoracic hnaging, 2008, 23:77 - 85.
  • 8Sarkar V,Shi C, Rassiah - Szegedi P, et al. The effect of a limited number of projections and reconstruction algorithms on the image quality of megavoltage digital tomosynthesis [ J ]. Appl Clin Med Phys,2009,10(3) :2970.
  • 9Feldkamp LA, Davis LC, Kress JW. Practical cone - beam algorithm[ J]. J Opt Soc AMA,2004,1:612 - 619.
  • 10Stitik FP, tockma MS. Radiaographic screening in the early detection of lung cancer [J] Radiol Clin N Am, 1978,16 (3) :347 -366.

二级参考文献28

  • 1Stitik FP,Tockman MS.Radiographic screening in the early detection of lung cancer[J].Radiol Clin N Am,1978,16(3):347-366.
  • 2Ren L,Zhang J,Thongphiew D,et al.A novel digital tomosynthesis(DTS)reconstruction method using a deformation field map[J].Med Phys,2008,35(7):3110-3115.
  • 3Yan H,Godfrey DJ,Yin FF.Fast reconstrution of digital tomosynthesis using on-board images[J].Med Phys,2008,35(5):2162-2169.
  • 4James T.Dobbins III,H Page McAdams.Digital tomosynthesis of the chest[J].J ThoracImaging,2008,23(1):86-92.
  • 5Dobbins JT III,Godfrey DJ.Digital X-ray tornosynthesis:current state of the art and clinical potential[J].Phys Med Biol,2003,48(19):R65-R106.
  • 6Godfrey DJ,McAdams HP,Dobbins JT III.Optimization of matrix inversion tomosynthesis(MITS)impulse response and modulation transfer function characteristics for chest imaging[J].Med Phys JT,2006,33(3):655-667.
  • 7Bliznakova K,Kolitsi Z,Speller RD,et al.Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry[J].Med Phys JT,2010,37(4):1893-903.
  • 8Duryea J,Dobbins JT 3rd,Lynch JA.Digital tomosynthesis of hand joints for arthritis assessment[J].Med Phys,2003,30(3):325-333.
  • 9Fuji.K,Aoyama T,Koyama S,et al.Comparative evaluation of organ and effective dose for pediatric patients with those for adults an chest and abdominal CT examinations[J].Br J Radio1,2007,80(956):657-667.
  • 10James TD,McAdams HP,Song JW,et al.Digital tomosynthesis of the chest for lung nodule detection:interim sensitivity results from an ongoing NIH-sponsored trial[J].Med Phys,2008,35(6):2554-2557.

共引文献43

同被引文献17

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部