期刊文献+

基于健侧三维数字解剖的桡骨头假体逆向工程研究 被引量:3

The reverse engineering of radial head prosthesis: based on three-dimensional digital anatomy of proximal radius on uninjured side
下载PDF
导出
摘要 目的探讨基于健侧三维数字解剖结构逆向工程个体化计算机辅助设计桡骨头假体的方法以提供临床精确置换。方法采用GE Speed Light 16排螺旋CT薄层扫描健康成人1例双侧肘关节,排除桡骨头疾患,获取CT扫描dicom数据导入Mimics10.0软件三维重建肘关节。提取左健侧桡骨近端三维模型经镜像模拟右患侧桡骨近端,再经编辑处理分割为头颈两部分。利用Mimics10.0软件测量颈段髓内径、长度参数构建假体柄。桡骨头模型导入Geomagic studio 12软件模拟软骨加厚处理,导入假体柄模型生成头柄部实体。按解剖特点虚拟组装头柄部件,实现患侧桡骨头假体的逆向工程。结果依据健侧肘关节CT影像数据,利用Mimics和Geomagic studio软件,进行三维重建,编辑,测量和反求,可实现个体化桡骨头假体设计和头柄部件的虚拟组装成型。结论基于健侧桡骨数字解剖的逆向工程为个体化桡骨头假体的研制提供了一个有效的方法。 Objoelive To study the reverse engineering of radial head prosthesis based on three-dimensional digital anatomy of proximal radius on uninjured side with the technique of computer aided design in order to help the clinical accurate replacement. Methods The double elbow joints of a healthy adult was thin slice scaned by GE Speed Light 16 CT to obtain the CT dicom data, which were then imported into Mimics 10.0 software for reconstruction of the 3D image of the elbow joints. Establish the mirror image of the proximal segment of the radius on the left side which was presumed unjuried. Then edit and cut it into the head and neck sections, configure the stem tlrough measurement of the diameter and length of the neck intermedullary canal. Meanwhile, the head DXF file was imported into Geomagic studio 12 , Finally, the reverse engineering of the radial head prosthesis was finished. Results By 3D reconstruction, edit, measurement and manipulation of the CT image data of the proximal radius on uninjured side in Mimicsl0.0 and Geomagic studio 12 software can reversely design the individual radial head prosthesis and simulate to make it up. Conclusion Reverse engineering based on three-dimensional digital anatomy of the proximal radius on the uninjured side provides an effective method to produce an individual radial head prosthesis.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2013年第4期407-410,共4页 Chinese Journal of Clinical Anatomy
基金 江苏省海门市社会发展科技计划项目(SHS 201102)
关键词 桡骨头 解剖 三维重建 个体化假体 逆向工程 Radial head Anatomy 3D reconstruction Individua prosthesis Reverse engineering
  • 相关文献

参考文献20

  • 1Harrington IJ, Sekyi-Otu A, Barrington TW, et al. The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures:a long-term review[J]. J Trauma,2001,50(1) :46-52.
  • 2Van Riet RP, Sanchez-Sotelo J, Morrey BF. Failure of metal radial head replacement[J].J Bone Joint Surg Br,2010,92(5):661-667.
  • 3Flinkkilo T, Kaisto T, Simio K, et al. Short- to mid-term results of metallic press-fit radial head arthroplasty in unstable injuries of the elbow[J]. J Bone Joint Surg Br, 2012,94(6):805-810.
  • 4罗滨.肱骨远端解剖参数相关性分析与假体个体化设计[J].中国临床解剖学杂志,2007,25(4):409-410. 被引量:4
  • 5朱志刚,金大地,罗吉伟,陈国奋,景宗森.股骨远端解剖形态性别差异与假体形态设计的关系[J].中国临床解剖学杂志,2008,26(4):386-388. 被引量:15
  • 6朱建炜,刘璠,张烽,董启榕,许炜玮,白恩忠,黄希.基于CT三维重建个体化股骨假体计算机辅助设计:满足假体与病变骨骼的匹配度[J].中国组织工程研究与临床康复,2008,12(17):3233-3236. 被引量:4
  • 7Gupta GG, Moore-Jansen PH, Lucas G. Differences in radial head dimensions based on gender, age and side [J]. Orthop Trans, 1992,15(4): 758-760.
  • 8King G, Zarzour Z, Patterson S, et al. An anthropometric study of the radial head: implications in the design of a prosthesis [J].Arthroplasty, 2001,16(1):112-116.
  • 9Schmidt-Horlohe K, Siebenlist S, St?ckle U,et al. Fractures of the radial head and neck[J].J Orthop Unfall, 2011,149(6):69-86.
  • 10Yian E, Steens W, Lingenfelter E, et al. Malpositioning of radial head prostheses: an in vitro study [J]. J Shoulder Elbow Surg, 2008 ,17 (4): 663 -670.

二级参考文献57

共引文献55

同被引文献67

  • 1刘世峰,崔文波,廖志峰,邝铭业,张炯涛.股骨近端锁定解剖加压钢板治疗老年股骨粗隆间骨折[J].中国继续医学教育,2013,5(4):4-6. 被引量:3
  • 2董纪元,张健,王岩.根据患者类型选择不同类型人工膝关节假体植入后临床应用效果的回顾性分析(英文)[J].中国组织工程研究与临床康复,2007,11(8):1563-1566. 被引量:5
  • 3Simion M, Rocchietta I, Monforte M, et al. Three-dimensional alveolar bone reconstruction with a combination of recombinant human platelet-derived growth factor BB and guided bone regeneration: a case report. Int J Periodont Restorat Dent. 2008;28(3):239-243.
  • 4Koyama Y, Kikuchi M, Edamura K, et al. Reconstruction of bone fenestration on mandiblar by the guided bone regeneration methods with beta-TCP/PLGC membranes. J Nanosci Nanotechnol. 2007:7('3~:859-861.
  • 5Jardini AL, Larosa MA, Filho RM. Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing. J Cranio Maxillo Facial Surg. 2014;1(8): 1-8.
  • 6Victorian G, Michael R, Robert LB, et al. Reduced wear with oxidized zirconium femoral heads. J Bone Joint Surg Am. 2003;85:105-110.
  • 7Kim H J, Chun H J, Kang KT, et al. A validated finite element analysis of never root stress in degenerative lumbar scoliosis. Med Biol Eng Comput. 2009;47(6):559-605.
  • 8Ciocca L, Scotti R. CAD-CAM generated ear cast by means of a laser scanner and rapid prototyping machine. Prosthet Dent. 2004;92(6):591-595.
  • 9Bistolfi A, Massazza G, Rosso F, et aI.Cemented fixed-bearing PFC total knee arthroplasty: survival and failure analysis at 12-17 years. J Orthop Traumatol. 2011 ;12(3):131-136.
  • 10Swank ML, Korbee L.Computer-Assisted Surgery in Total Knee Arthroolastv. Tech Knee Sura. 2006:5(41: 228-237.

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部